Background: In coronary computed tomography angiography (CCTA), the main issue of image quality is noise in obese patients, blooming artifacts due to calcium and stents, high-risk coronary plaques, and radiation exposure to patients.

Objective: To compare the CCTA image quality of deep learning-based reconstruction (DLR) with that of filtered back projection (FBP) and iterative reconstruction (IR).

Methods: This was a phantom study of 90 patients who underwent CCTA. CCTA images were acquired using FBP, IR, and DLR. In the phantom study, the aortic root and the left main coronary artery in the chest phantom were simulated using a needleless syringe. The patients were classified into three groups according to their body mass index. Noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured for image quantification. A subjective analysis was also performed for FBP, IR, and DLR.

Results: According to the phantom study, DLR reduced noise by 59.8% compared to FBP and increased SNR and CNR by 121.4% and 123.6%, respectively. In a patient study, DLR reduced noise compared to FBP and IR. Furthermore, DLR increased the SNR and CNR more than FBP and IR. In terms of subjective scores, DLR was higher than FBP and IR.

Conclusion: In both phantom and patient studies, DLR effectively reduced image noise and improved SNR and CNR. Therefore, the DLR may be useful for CCTA examinations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10252561PMC
http://dx.doi.org/10.3390/diagnostics13111862DOI Listing

Publication Analysis

Top Keywords

image quality
12
phantom study
12
snr cnr
12
deep learning-based
8
learning-based reconstruction
8
phantom patient
8
patient studies
8
dlr
8
fbp dlr
8
study dlr
8

Similar Publications

Background: Locoregional external beam radiotherapy (EBRT) is selectively used in thyroid cancer patients to induce locoregional control. However, despite technological advances, EBRT remains associated with toxicities. We evaluated thyroid-cancer specific toxicities and long-term Quality of Life (QoL) post-EBRT.

View Article and Find Full Text PDF

Colony-stimulating factor 1 receptor (CSF1R) is almost exclusively expressed on microglia in the human brain and thus, has promise as a biomarker for imaging microglia density as a proxy for neuroinflammation. [C]CPPC is a radiotracer with selective affinity to CSF1R, and has been evaluated for in-human microglia PET imaging. The flourine-18 labeled CPPC derivative, 5-cyano-N-(4-(4-(2-[F]fluoroethyl)piperazin-1-yl)-2-(piperidin-1-yl)phenyl)furan-2-carboxamide ([F]FCPPC), was previously synthesized, however, with a low radiochemical yield using manual radiosynthesis.

View Article and Find Full Text PDF

Background: Bedside thoracic ultrasound (US) offers numerous advantages over chest X-ray (CXR) for identification of recurrent pneumothoraces (PTX) after tube thoracostomy (TT) removal. Technologic advancements have led to the development of hand-held devices capable of producing high-quality images termed ultra-portable US (UPUS). We hypothesized that UPUS would be as successful as CXR in detecting post-TT removal PTX and would be preferred by patients.

View Article and Find Full Text PDF

In the field of agriculture, particularly within the context of machine learning applications, quality datasets are essential for advancing research and development. To address the challenges of identifying different mango leaf types and recognizing the diverse and unique characteristics of mango varieties in Bangladesh, a comprehensive and publicly accessible dataset titled "BDMANGO" has been created. This dataset includes images essential for research, featuring six mango varieties: Amrapali, Banana, Chaunsa, Fazli, Haribhanga, and Himsagar, which were collected from different locations.

View Article and Find Full Text PDF

Aberrant anatomical variation of the vertebral artery (VA) from an internal carotid artery (ICA) is considered a rare finding. The incidence of this phenomenon can lead to patients suffering from posterior circulation neurological deficit if the ICA becomes significantly diseased. VA atypical anatomical origin is considered one of the rare pathologies, not only precipitating neurovascular incidents but equally leading to severe difficulty in VA dissection and surgical exposure, especially in carotid artery procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!