A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of Stroke Volume With Echocardiography Compared to Gold Standard Cardiac Magnetic Resonance Imaging: An Observational Study. | LitMetric

Objectives: The authors aimed to compare the assessment of left ventricular (LV) stroke volume with transthoracic echocardiography (TTE) using 2- and 3-dimensional (2D and 3D) Doppler and volumetric techniques with gold standard cardiac magnetic resonance imaging (CMR).

Design: An observational study.

Setting: A medical research institute.

Participants: A total of 187 volunteer participants free of known structural heart disease.

Interventions: None.

Measurements And Main Results: LV stroke volume was measured with TTE using the following 4 techniques: LV outflow tract (LVOT) pulsed wave Doppler with 2D LVOT area, LVOT pulsed wave Doppler with 3D LVOT area, 2D volumetric (Simpson's biplane), and 3D volumetric techniques. This was compared with gold standard CMR. Stroke volume measured with echocardiography underestimated stroke volume compared to CMR by all techniques (p < 0.001 for all values compared to CMR). The LVOT Doppler stroke volume with a 3D area most closely agreed with CMR, with a bias of 6.35%. This bias progressively increased with 3D volumetric (13.4%), LVOT Doppler with a 2D area (15.1%), and 2D volumetric (18.3%) stroke volume techniques, with wider limits of agreement.

Conclusion: Of the 4 echocardiographic LV stroke volume measurement methods the authors assessed, stroke volume with LVOT Doppler using 3D measurement of LVOT area most closely approximates gold standard CMR.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2023.05.024DOI Listing

Publication Analysis

Top Keywords

stroke volume
36
gold standard
16
lvot area
12
lvot doppler
12
volume
9
compared gold
8
standard cardiac
8
cardiac magnetic
8
magnetic resonance
8
resonance imaging
8