Current-induced spin-orbit torques (SOTs) enable fast and efficient manipulation of the magnetic state of magnetic tunnel junctions (MTJs), making them attractive for memory, in-memory computing, and logic applications. However, the requirement of the external magnetic field to achieve deterministic switching in perpendicularly magnetized SOT-MTJs limits its implementation for practical applications. Here, we introduce a field-free switching (FFS) solution for the SOT-MTJ device by shaping the SOT channel to create a "bend" in the SOT current. The resulting bend in the charge current creates a spatially nonuniform spin current, which translates into inhomogeneous SOT on an adjacent magnetic free layer enabling deterministic switching. We demonstrate FFS experimentally on scaled SOT-MTJs at nanosecond time scales. This proposed scheme is scalable, material-agnostic, and readily compatible with wafer-scale manufacturing, thus creating a pathway for developing purely current-driven SOT systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10311595 | PMC |
http://dx.doi.org/10.1021/acs.nanolett.3c00639 | DOI Listing |
World J Radiol
January 2025
Department of Medical Imaging, Anqing Hospital Affiliated to Anhui Medical University, Anqing 246000, Anhui Province, China.
Background: Fistula-in-ano is an abnormal tunnel formation linking the anal canal with the perineum and perianal skin. Multiple imagining methods are available to evaluate it, among which magnetic resonance imaging (MRI) is the most advanced noninvasive preoperative method. However, it is limited in its visualization function.
View Article and Find Full Text PDFPlast Surg (Oakv)
February 2025
Division of Plastic and Reconstructive Surgery, Memorial University, St. John's, Newfoundland, Canada.
Given the proximity and shared structures of Guyon's canal and the carpal tunnel, compression of the ulnar nerve is a rarely observed but possible complication of carpal tunnel release. In this case report, a patient underwent previous carpal tunnel release and immediately experienced ipsilateral hand weakness in keeping with an ulnar nerve compression syndrome. Clinical, electrodiagnostic, and magnetic resonance imaging findings after carpal tunnel release demonstrated a compression or injury to the deep motor branch of the ulnar nerve not previously present.
View Article and Find Full Text PDFJ Orthop
August 2025
Department of Orthopaedic Surgery, Antwerp University Hospital, 2650, Edegem, Belgium.
Purpose: Wide acceptance of arthroscopically treating posterolateral corner injuries has not occurred. There remains a fear of neurovascular (NV) injury while arthroscopically performing these reconstructions. The study's aim is to compare on Magnetic Resonance Scans the distance of the tibial tunnel in an arthroscopic popliteus tendon reconstruction (APB) and arthroscopic posterior cruciate ligament (PCL) reconstruction (APC) to the popliteal neurosvascular bundle.
View Article and Find Full Text PDFSci Rep
January 2025
School of Earth Sciences, China University of Geosciences, Wuhan, 430074, Hubei, China.
Soil magnetic records in Quaternary red earth (QRE) deposits contain a valuable record of paleoclimate information, providing insights into controls on Earth's climate system in the past and potentially helping to predict its response to perturbations in the future. Here, analysis of the environmental magnetism and mineralogy of the Xuancheng QRE (Anhui Province, South China) shows that magnetic variation was strongly linked to production of authigenic ferrimagnetic minerals such as maghemite. Fine-grained maghemite formed during the weathering-related transformation of iron-bearing illite to vermiculite, generating aggregates of vermiculite or mixed-layer illite-vermiculite.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!