Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Various surface modifications are used in uncemented total knee arthroplasties (TKAs) to enhance bony ingrowth and longevity of implants. This study aimed to identify which surface modifications are used, whether they are associated with different revision rates for aseptic loosening, and which are underperforming compared to cemented implants.
Methods: Data on all cemented and uncemented TKAs used between 2007 and 2021 were obtained from the Dutch Arthroplasty Register. Uncemented TKAs were divided into groups based on their surface modifications. Revision rates for aseptic loosening and major revisions were compared between groups. Kaplan-Meier, Competing-Risk, Log-rank tests, and Cox regression analyses were used. In total, 235,500 cemented and 10,749 uncemented primary TKAs were included. The different uncemented TKA groups included the following: 1,140 porous-hydroxyapatite (HA); 8,450 Porous-uncoated; 702 Grit-blasted-uncoated; and 172 Grit-blasted-Titanium-nitride (TiN) implants.
Results: The 10-year revision rates for aseptic loosening and major revision of the cemented TKAs were 1.3 and 3.1%, and for uncemented TKAs 0.2 and 2.3% (porous-HA), 1.3 and 2.9% (porous-uncoated), 2.8 and 4.0% (grit-blasted-uncoated), and 7.9% and 17.4% (grit-blasted-TiN), respectively. Both type of revision rates varied significantly between the uncemented groups (log-rank tests, P < .001, P < .001). All grit-blasted implants had a significantly higher risk of aseptic loosening (P < .01), and porous-uncoated implants had a significantly lower risk of aseptic loosening than cemented implants (P = .03) after 10 years.
Conclusion: There were 4 main uncemented surface modifications identified, with different revision rates for aseptic loosening. Implants with porous-HA and porous-uncoated had the best revision rates, at least equal to cemented TKAs. Grit-blasted implants with and without TiN underperformed, possibly due to the interaction of other factors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2023.05.094 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!