Traumatic bone fractures are often debilitating injuries that may require surgical fixation to ensure sufficient healing. Currently, the most frequently used osteosynthesis materials are metal-based; however, in certain cases, such as complex comminuted osteoporotic fractures, they may not provide the best solution due to their rigid and non-customizable nature. In phalanx fractures in particular, metal plates have been shown to induce joint stiffness and soft tissue adhesions. A new osteosynthesis method using a light curable polymer composite has been developed. This method has demonstrated itself to be a versatile solution that can be shaped by surgeons in situ and has been shown to induce no soft tissue adhesions. In this study, the biomechanical performance of AdhFix was compared to conventional metal plates. The osteosyntheses were tested in seven different groups with varying loading modality (bending and torsion), osteotomy gap size, and fixation type and size in a sheep phalanx model. AdhFix demonstrated statistically higher stiffnesses in torsion (64.64 ± 9.27 and 114.08 ± 20.98 Nmm/° vs. 33.88 ± 3.10 Nmm/°) and in reduced fractures in bending (13.70 ± 2.75 Nm/mm vs. 8.69 ± 1.16 Nmm/°), while the metal plates were stiffer in unreduced fractures (7.44 ± 1.75 Nm/mm vs. 2.70 ± 0.72 Nmm/°). The metal plates withstood equivalent or significantly higher torques in torsion (534.28 ± 25.74 Nmm vs. 614.10 ± 118.44 and 414.82 ± 70.98 Nmm) and significantly higher bending moments (19.51 ± 2.24 and 22.72 ± 2.68 Nm vs. 5.38 ± 0.73 and 1.22 ± 0.30 Nm). This study illustrated that the AdhFix platform is a viable, customizable solution that is comparable to the mechanical properties of traditional metal plates within the range of physiological loading values reported in literature.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10250346 | PMC |
http://dx.doi.org/10.1038/s41598-023-35706-3 | DOI Listing |
J Dent Educ
December 2024
Instituto de Odontoestomatología, Escuela de Odontología, Facultad de Medicina, Universidad Austral de Chile, Valdivia, Chile.
Aim: To compare thequality and accuracy of radiographic images obtained by dentistry students from a Chilean university using photostimulable phosphor plates (PSP) and complementary metal oxide semiconductor (CMOS) receptors.
Materials And Methods: An experimental study was carried out in which 31 dental students used PSP and CMOS receptors to acquire radiographic images with the aid of a phantom. The time required to generate a radiograph was recorded.
J Colloid Interface Sci
December 2024
China Auto Information Technology Co., Ltd, Tianjin 300300, People's Republic of China.
Angew Chem Int Ed Engl
December 2024
University of Maryland at College Park, Department of Chemical & Biomolecular Engineering, 1223A Chemical and Nuclear Engineering, 20742, College Park, UNITED STATES OF AMERICA.
All-solid-state Li-metal battery (ASSLB) chemistry with thin solid-state electrolyte (SSE) membranes features high energy density and intrinsic safety but suffers from severe dendrite formation and poor interface contact during cycling, which hampers the practical application of rechargeable ASSLB. Here, we propose a universal design of thin Li-metal anode (LMA) via a dynamic stability strategy to address these issues. The ultra-thin LMA (20 μm) is in-situ constructed with uniform highly Li-ion conductive solid-electrolyte interphase and composite-polymer interphase (CPI) via electroplating process.
View Article and Find Full Text PDFWater Res
December 2024
Department of Neurobiology and Acupuncture Research, The Third Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, 310053, PR China. Electronic address:
While technological advancements in treating electroplating wastewater continue, removing high concentrations of Ni and Co remains a challenge. Surface functionalization of clay has emerged as a pivotal approach for effectively removing heavy metals, rivaling intercalation modification in its effectiveness. This study investigated the adsorption performance and mechanisms of a phosphonate-modified layered double hydroxide material, employing batch experiments and simulation calculations to elucidate the impact of surface modification on adsorption behavior.
View Article and Find Full Text PDFDent Med Probl
December 2024
Department of Prosthetic Dentistry and Gerodontology, Poznan University of Medical Sciences, Poland.
Background: Ceramic endosseous implant coatings have gained esteem due to their favorable osteoinductive and osteoconductive properties. However, such a layer may be prone to failure under in vivo conditions, which necessitates its modification.
Objectives: The aim of the present study was to modify an electrodeposited hydroxyapatite (HA) coating on titanium (Ti) with ultrashort-pulsed lasers for the incorporation of the ceramic into the sample surface and the texturing of the metal surface.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!