The need to acquire multiple angle-resolved electron energy loss spectra (EELS) is one of the several critical challenges associated with electron magnetic circular dichroism (EMCD) experiments. If the experiments are performed by scanning a nanometer to atomic-sized electron probe on a specific region of a sample, the precision of the local magnetic information extracted from such data highly depends on the accuracy of the spatial registration between multiple scans. For an EMCD experiment in a 3-beam orientation, this means that the same specimen area must be scanned four times while keeping all the experimental conditions same. This is a non-trivial task as there is a high chance of morphological and chemical modification as well as non-systematic local orientation variations of the crystal between the different scans due to beam damage, contamination and spatial drift. In this work, we employ a custom-made quadruple aperture to acquire the four EELS spectra needed for the EMCD analysis in a single electron beam scan, thus removing the above-mentioned complexities. We demonstrate a quantitative EMCD result for a beam convergence angle corresponding to sub-nm probe size and compare the EMCD results for different detector geometries.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2023.113760DOI Listing

Publication Analysis

Top Keywords

3-beam orientation
8
quadruple aperture
8
aperture acquire
8
emcd
5
single scan
4
scan stem-emcd
4
stem-emcd 3-beam
4
orientation quadruple
4
acquire multiple
4
multiple angle-resolved
4

Similar Publications

Noise-dependent bias in quantitative STEM-EMCD experiments revealed by bootstrapping.

Ultramicroscopy

March 2024

Department of Materials and Environmental Chemistry, Stockholm University, Stockholm 106 91, Sweden.

Electron magnetic circular dichroism (EMCD) is a powerful technique for estimating element-specific magnetic moments of materials on nanoscale with the potential to reach atomic resolution in transmission electron microscopes. However, the fundamentally weak EMCD signal strength complicates quantification of magnetic moments, as this requires very high precision, especially in the denominator of the sum rules. Here, we employ a statistical resampling technique known as bootstrapping to an experimental EMCD dataset to produce an empirical estimate of the noise-dependent error distribution resulting from application of EMCD sum rules to bcc iron in a 3-beam orientation.

View Article and Find Full Text PDF

Single scan STEM-EMCD in 3-beam orientation using a quadruple aperture.

Ultramicroscopy

September 2023

Department of Materials Science and Engineering, Uppsala University, Box 534, 75121, Uppsala, Sweden.

The need to acquire multiple angle-resolved electron energy loss spectra (EELS) is one of the several critical challenges associated with electron magnetic circular dichroism (EMCD) experiments. If the experiments are performed by scanning a nanometer to atomic-sized electron probe on a specific region of a sample, the precision of the local magnetic information extracted from such data highly depends on the accuracy of the spatial registration between multiple scans. For an EMCD experiment in a 3-beam orientation, this means that the same specimen area must be scanned four times while keeping all the experimental conditions same.

View Article and Find Full Text PDF

Ionizing radiation causes chromosome aberrations, which are possible biomarkers to assess space radiation cancer risks. Using the Monte Carlo codes Relativistic Ion Tracks (RITRACKS) and Radiation-Induced Tracks, Chromosome Aberrations, Repair and Damage (RITCARD), we investigated how geometrical properties of the cell nucleus, irradiated with ion beams of linear energy transfer (LET) ranging from 0.22 keV/μm to 195 keV/μm, influence the yield of simple and complex exchanges.

View Article and Find Full Text PDF

Purpose: To model whether in vivo range verification could reduce high-grade rectal toxicity for patients with prostate cancer treated with pencil beam scanning proton therapy by allowing novel proton beam arrangements compared to standard lateral opposed beams.

Materials And Methods: Proton plans were generated for 8 patients with prostate cancer previously treated with photons by volumetric-modulated arc therapy (VMAT). The VMAT plans were generated by using a uniform 6-mm planning target volume (PTV) expansion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!