A modified methylmethacrylate cranioplasty is presented. After preparation of the skull defect, a Teflon net is placed and fitted over it, overlapping the border by one centimeter. The plastic material is spread over the Teflon net in the skull defect and is removed as soon as it becomes firm. Next, the plate is perforated at several points and then is fixed with Vicryl stiches between the Teflon net and the epicranium. This procedure is simple and fast. The fixation is firm; the result is good.

Download full-text PDF

Source

Publication Analysis

Top Keywords

teflon net
12
skull defect
8
cranioplasty acrylic
4
acrylic methyl
4
methyl methacrylate
4
methacrylate resin
4
resin modified
4
modified procedure--technical
4
procedure--technical note
4
note modified
4

Similar Publications

Triboelectric nanogenerators (TENGs), among the most simple and efficient means to harvest mechanical energy, have great potential in renewable energy utilization. While the output performance of TENGs is still not high enough, which limits its practical application. Here, a poly(vinylidene fluoride) (PVDF)/fluorinated ethylene propylene nanoparticles (FEP NPs) porous nanofiber (PFPN) membrane with waterproof, breathable, surface superhydrophobic and high tribo-negative properties is proposed for achieving high-performance of TENGs.

View Article and Find Full Text PDF

Development of a net ozone production rate detection system based on dual-channel cavity ring-down spectroscopy.

J Environ Sci (China)

March 2025

School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei 230026, China; Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China. Electronic address:

A novel system for measuring net photochemical ozone production rates in the atmosphere based on cavity ring-down spectroscopy (OPR-CRDS) was developed. The system consists of two chambers (a reaction chamber and a reference chamber) and a dual-channel O-CRDS detector. To minimize the wall loss of O in the chambers, the inner surfaces of both chambers are coated with Teflon film.

View Article and Find Full Text PDF

A 61-year-old woman, referred for recurrent pneumonia over a period of 3 months with insufficient response to antibiotic treatment, presented with coughing and intense right-sided chest pain. Previously, she underwent right upper lobectomy for locally advanced non-small cell lung cancer (squamous cell carcinoma) followed by adjuvant chemotherapy and subsequent partial chest wall resection with polytetrafluoroethylene net insert due to a pleurocutaneous fistula. 18 FDG plus a 68 Ga-labeled fibroblast activation protein inhibitor ( 68 Ga-FAPI) PET/CT scans were performed to rule out non-small cell lung cancer recurrence.

View Article and Find Full Text PDF

Long-term Outcomes of Polytetrafluoroethylene Bicuspid Pulmonary Valve Replacement.

Ann Thorac Surg

March 2024

Department of Statistics and Actuarial Science, Soongsil University, Seoul, Republic of Korea.

Background: In 2016 we reported promising midterm outcomes of bicuspid pulmonary valve replacement using 0.1-mm polytetrafluoroethylene (PTFE) membrane. This follow-up study analyzes long-term outcomes and risk factors for reintervention and structural valve deterioration (SVD).

View Article and Find Full Text PDF

High-accuracy total reflection X-ray fluorescence analysis for determining trace elements using substrate cleaned by ammonia-hydrogen peroxide mixture.

Talanta

December 2023

Division of Science and Engineering for Materials, Chemistry and Biology Department of Chemistry and Bioengineering, Osaka Metropolitan University, 3-3-138 Sugimoto, Sumiyoshi, Osaka, 558-8585, Japan.

Total reflection X-ray fluorescence (TXRF) analysis is one of the useful techniques for determining trace elements. Owing to the high detection sensitivity of X-ray fluorescence in small residues, the hydrophobic substrates are generally used to form dot-type residue. However, when measuring low-Z elements in sample solutions with high concentrations of matrix elements, obtaining sufficient measurement sensitivity can be difficult.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!