  • The study compared fatigue resistance (FR) during grip strength tests using two different handgrip systems and explored how age and clinical status affect results.
  • A range of participants, including young healthy individuals, middle-aged, older adults, and hospitalized geriatric patients, underwent the FR test, which measured how long grip strength could be sustained before declining to half its maximum.
  • Results indicated that there were significant associations in force-time data between grip strength measured during full and reduced test durations, as well as notable differences in performance based on age group, particularly in the initial strength decay.

Article Abstract

Introduction: Fatigue resistance (FR) can be assessed as the time during which grip strength (GS) drops to 50% of its maximum during a sustained maximal voluntary contraction. For the first time, we compared force-time characteristics during FR test between two different handgrip systems and investigated age- and clinical-related differences in order to verify if a briefer test protocol (i.e., until 75%) could be sufficiently informative.

Methods: A cohort of young healthy controls (Y, <30 y, 24 ± 3 y, 54% women), middle-aged (MA, 30-65 y, 47 ± 11 y, 54% women), and older (OLD, >65 y, 77 ± 7 y, 50% women) community-dwelling persons, and hospitalized geriatric patients (HOSP, 84 ± 5 y, 50% women) performed the FR test. For this purpose, an adapted vigorimeter (original rubber bulb of the Martin Vigorimeter connected to a Unik 5000 pressure gauge) here defined as "pneumatic handgrip system" (Pneu) and Dynamometer G200 system (original Jamar Dynamometer handle with an in-build strength gauge) here defined as "hydraulic handgrip system" (Hydr) were used. Force-time curves were analysed from 100% to 75% and from 75% to 50% of the initial maximal GS during the FR test. The area under the curve (GW) was calculated by integrating the actual GS at each time interval (i.e., 1/5,000 s) and corrected for body weight (GW/body weight).

Results: For both systems, we found fair associations between FR100-50 and FR100-75 (Pneu mean difference = 50.1 s [95% CI: 47.9-52.4], r2 = 0.48; Hydr mean difference = 28.4 s [95% CI: 27.0-29.7], r2 = 0.52, all p < 0.001) and also moderate associations between GW(100-50)/body weight and GW(100-75)/body weight (Pneu mean difference = 32.1 kPa*s/kg [95% CI: 30.6-33.6], r2 = 0.72; Hydr mean difference = 8.1 kg*s/kg [95% CI: 7.7-8.6], r2 = 0.68, all p < 0.001). Between MA and OLD, we found a significant age-related difference in the GW results in the first 25% strength decay for Pneu (10.2 ± 0.6 kPa*s/kg against 7.1 ± 1.2 kPa*s/kg, respectively).

Conclusion: The brief test protocol is valid. Differences within the first 25% strength decay in GW between OLD and HOSP were identified when using Pneu but not when using Hydr. Therefore, a brief FR test protocol using a continuous registration of the strength decay seems to be sufficiently informative in a clinical setting to appraise muscle fatigability, however, only when using a Pneu system.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000530227DOI Listing

Publication Analysis

Top Keywords

test protocol
12
strength decay
12
handgrip systems
8
54% women
8
50% women
8
gauge defined
8
handgrip system"
8
pneu difference
8
hydr difference
8
25% strength
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!