Anastomotic leaks (AL) and staple line leaks are a serious post-operative complication that can develop following bariatric surgery. The delay in the onset of symptoms following a leak usually results in reactive diagnostics and treatment, leading to increased patient morbidity and mortality, and a clinical and economic burden on both the patient and the hospital. Despite support in literature for pH as a biomarker for early detection of AL, the current methods of pH detection require significant clinician involvement and resources. Presented here is a polyaniline (PANI)-based pH sensor that can be connected inline to surgical drains to continuously monitor peritoneal secretion in real time for homeostatic changes in pH. During this study, the baseline peritoneal fluid pH was measured in two pigs using the PANI sensor and verified using a benchtop pH probe. The PANI sensor was then utilized to continuously monitor the changes in the pH of peritoneal effluent, as a gastric leak was simulated. The inline sensors were able to detect the resulting local changes in drainage pH within 10 min of leak induction. The successful implementation of this sensor in clinical practice can both enable high efficiency continuous monitoring of patient status and drastically decrease the time required to detect AL, thus potentially decreasing the clinical and economic burden incurred by gastric leaks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10235488PMC
http://dx.doi.org/10.3389/fmedt.2023.1128460DOI Listing

Publication Analysis

Top Keywords

continuous monitoring
8
early detection
8
anastomotic leaks
8
clinical economic
8
economic burden
8
continuously monitor
8
pani sensor
8
sensor
5
monitoring sensor
4
sensor early
4

Similar Publications

Testing an Electronic Patient-Reported Outcome Platform in the Context of Traumatic Brain Injury: PRiORiTy Usability Study.

JMIR Form Res

January 2025

Centre for Patient Reported Outcomes Research, Institute of Applied Health Research, University of Birmingham, Birmingham, United Kingdom.

Background: Traumatic brain injury (TBI) is a significant public health issue and a leading cause of death and disability globally. Advances in clinical care have improved survival rates, leading to a growing population living with long-term effects of TBI, which can impact physical, cognitive, and emotional health. These effects often require continuous management and individualized care.

View Article and Find Full Text PDF

Novel continuous and quantitative intraoperative facial nerve-monitoring system for temporal bone lesions.

Eur Arch Otorhinolaryngol

January 2025

Department of Otorhinolaryngology-Head and Neck Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.

Objective: Intraoperative systems for monitoring facial nerve function, in which temporal electrical stimulation is applied to the facial nerve through electrodes, are used in many surgeries requiring facial nerve preservation; however, continuous stimulation or quantitative evaluation of facial nerve function is difficult with this approach. We examined the usefulness of a continuous and quantitative facial nerve-monitoring system for temporal bone lesions by using our experience to modify the existing methods used for cases involving vestibular schwannomas.

Study Design: Retrospective observational study.

View Article and Find Full Text PDF

Objectives: we evaluated the hypothesis that level of ctHPVDNA on the first postoperative day (POD-1); and at 15 days (POD-15) could be associated with the need for adjuvant therapy and the presence of recurrence.

Materials And Methods: this is a prospective observational study on biomarkers, focusing on the longitudinal monitoring of ctHPVDNA in a cohort of HPV-OPSCC patients undergoing TORS. Blood samples were collected according to the following schema: (1) pretreatment; (2) on first postoperative day (POD 1); and (3) at 15 days (POD 15).

View Article and Find Full Text PDF

Atrial arrhythmias, including atrial fibrillation (AF), are a major contributor to cardiovascular morbidity and mortality. Early detection and effective management are critical to mitigating adverse outcomes such as stroke, heart failure, and overall mortality. Wearable devices have emerged as promising tools for monitoring, detecting, and managing atrial arrhythmias near-continuously.

View Article and Find Full Text PDF

The Gravity Recovery and Climate Experiment (GRACE) and its follow-on (GRACE-FO) missions have provided estimates of Terrestrial Water Storage Anomalies (TWSA) since 2002, enabling the monitoring of global hydrological changes. However, temporal gaps within these datasets and the lack of TWSA observations prior to 2002 limit our understanding of long-term freshwater variability. In this study, we develop GRAiCE, a set of four global monthly TWSA reconstructions from 1984 to 2021 at 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!