Background: In the coronavirus disease 2019 (COVID-19) era, surgical resident education depends largely on virtual materials. With the help of point-of-view (POV) cameras, educational videos have become widely used for surgical training. A video recorded from the surgeon's POV helps demonstrate the procedure. We made training movies of the surgical approach to distal radius fractures for residents using a head-mounted video recording system with a laser point targeting device (LPTD).

Methods: A 15-minnute movie of the trans-flexor carpi radialis approach for distal radius fractures was made. A POV camera was assembled with an LPTD and strapped on the surgeon's head. This enabled maintenance of the surgical field while recording the procedure. A shorter version of the clip was also made to investigate trainee preference. We asked 24 trainees to watch the two versions of the video and complete a short questionnaire.

Results: All trainees felt that the movie made with a POV camera was more efficient than existing materials. Only 1 (4.2%) felt that the laser pointer hindered the view. Four of the 23 trainees (16.7%) felt dizzy while watching the video. Of the two versions, 16 trainees (66.7%) preferred the shorter, edited version. The average score for the video was 8.42 out of 10.

Conclusions: A video recording system in the operating room that uses an LPTD-POV camera is an efficient way to produce educational material, particularly for surgical residents during the COVID-19 era.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10232307PMC
http://dx.doi.org/10.4055/cios22172DOI Listing

Publication Analysis

Top Keywords

distal radius
12
radius fractures
12
resident education
8
covid-19 era
8
approach distal
8
video recording
8
recording system
8
pov camera
8
camera efficient
8
surgical
6

Similar Publications

Unlabelled: Metaphyseal comminution in distal radius fracture (DRF) cases might indicate severe osteoporosis. The patients with DRFs and metaphyseal comminution showed 5.2-fold increased secondary fractures compared with those receiving combination osteoporosis therapy.

View Article and Find Full Text PDF

Case: A 52-year-old male fell from his bike and sustained fractures of the right proximal humerus and the left distal radius, both of which were fixed in a single sitting a day after the injury. On postoperative day four, the patient developed features suggestive of acute pulmonary embolism.

Conclusion: Reports of acute pulmonary embolism developing after surgical fixation of bilateral upper extremity fractures are rare.

View Article and Find Full Text PDF

Background: Distal biceps tendon rupture is an injury that causes a significant reduction in strength and endurance. Combined cortical button and interference screw fixation has been utilized via single-incision technique. There are limited data describing this technique utilizing a double-incision approach.

View Article and Find Full Text PDF

High resolution peripheral quantitative computed tomography (HRpQCT) offers detailed bone geometry and microarchitecture assessment, including cortical porosity, but assessing chronic kidney disease (CKD) bone images remains challenging. This proof-of-concept study merges deep learning and machine learning to 1) improve automatic segmentation, particularly in cases with severe cortical porosity and trabeculated endosteal surfaces, and 2) maximize image information using machine learning feature extraction to classify CKD-related skeletal abnormalities, surpassing conventional DXA and CT measures. We included 30 individuals (20 non-CKD, 10 stage 3 to 5D CKD) who underwent HRpQCT of the distal and diaphyseal radius and tibia and contributed data to develop and validate four different AI models for each anatomical site.

View Article and Find Full Text PDF

BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!