Transcatheter aortic valve replacement has emerged as the preferred treatment modality in most patients with severe aortic stenosis. With its global adoption and broader application in younger and healthier patients, the issue of transcatheter bioprosthetic valve degeneration and its impact on valve durability continues to earn clinical relevance. Differences in the pathophysiologic processes that separate native from transcatheter heart valve deterioration remain poorly understood. When compared to surgical aortic bioprostheses, the mechanisms of valve degeneration are similar in transcatheter heart valves, with meaningful differences most noticeably found between the individual constructs of their design. Recognizing the clinical and hemodynamic presentation of structural valve degeneration remains paramount. The recently revised consensus guidelines that incorporate the integration of advanced multimodality imaging with invasive hemodynamics represent a major step forward in our ability to accurately diagnose bioprosthetic valve degeneration, and to identify differences in durability patterns, and to establish treatment recommendations for the lifetime management of patients with aortic stenosis. Parallel efforts to unmask the biomolecular differences in atherosclerotic plaque burden, valve calcification, and thrombotic diathesis, including host immunocompetence, between the different available bioprostheses, will further advance the role of emerging valve tissue technologies to improve durability. As with surgical heart valves, the optimal treatment options for redo-transcatheter aortic valve replacement and surgical explant remain poorly understood. Ongoing translational research in bench testing coupled with prospectively designed core lab-adjudicated clinical trials are much needed. This report provides a contemporary overview of transcatheter structural valve degeneration, including evolving concepts in its pathogenesis, diagnosis, and treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10236800PMC
http://dx.doi.org/10.1016/j.shj.2022.100155DOI Listing

Publication Analysis

Top Keywords

valve degeneration
20
structural valve
12
valve
11
valve deterioration
8
transcatheter aortic
8
aortic bioprostheses
8
aortic valve
8
valve replacement
8
aortic stenosis
8
bioprosthetic valve
8

Similar Publications

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

Background: Degenerative aortic valve disease (DAVD) is a multifactorial process. We developed an animal model to analyze the isolated, local effect of reactive oxygen species (ROS) on its pathophysiology.

Methods: We utilized a photodynamic reaction (PDR) as a source of ROS in the aortic valve by aiming a laser at the aortic valve for 60 min after the administration of a photosensitizer 24 h prior.

View Article and Find Full Text PDF

Purpose: Cardiac computed tomography angiography (CCTA) has significantly advanced the visualization of cardiac structures, particularly valves. We assessed the diagnostic performance of CCTA in diagnosing the most common disorders affecting the aortic valves requiring surgery-papillary fibroelastoma, infective endocarditis, and degeneration.

Methods: This retrospective study included patients who underwent aortic valve resection between 2016 and 2023 and had a preceding CCTA.

View Article and Find Full Text PDF

Background: Conduction disturbances are a frequent occurrence after tricuspid valve surgeries, and their management is challenging.

Case Presentation: We present a case of 16-year-old male patient who presented with episodes of presyncope. At the age of 7 years, he underwent tricuspid valve replacement surgery with a biological prosthesis for infective endocarditis sourced from a gluteal abscess.

View Article and Find Full Text PDF

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!