Introduction Two-stage revision is frequently used for the treatment of periprosthetic joint infection (PJI). Because antibiotic-loaded cement spacers are constructed and implanted as temporary devices, mechanical complications are possible. The purpose of our study was to define the incidence of such mechanical complications, determine associated risk factors, and establish if such complications influence the subsequent success of PJI treatment. Methods We identified patients who received an antibiotic spacer for the treatment of PJI at a single center over a six-year timeframe. Medical records and all radiographs were collected and reviewed. Radiographic changes over time were recorded, and mechanical complications were noted. We used multivariate logistic regression analysis to assess risk factors for mechanical spacer complications and assess whether such complications influence the likelihood of subsequent reimplantation and ultimate component retention. Results A total of 236 patients were included in the study. There were 82 hip spacers (28% dynamic and 72% static) with a mechanical complication rate of 8.5% and 154 knee spacers (44% dynamic and 56% static) with a mechanical complication rate of 18.2%. Knee spacers were significantly more likely to have mechanical complications than hip spacers. Other risk factors for mechanical complications included bone loss and elevated body mass index (BMI). Bone loss and advanced age were found to be independent risk factors for failure to undergo second-stage reimplantation. Mechanical spacer failure was not an independent risk factor for the likelihood of subsequent reimplantation or ultimate component retention. Conclusions Mechanical complications of antibiotic spacers are common but do not appear to negatively impact the likelihood of subsequent reimplantation or component retention. In knee spacers and in patients with bone loss or elevated BMI, appropriate patient counseling and strategies to prevent such complications are recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10238283PMC
http://dx.doi.org/10.7759/cureus.38496DOI Listing

Publication Analysis

Top Keywords

mechanical complications
28
knee spacers
16
risk factors
16
likelihood subsequent
12
subsequent reimplantation
12
component retention
12
bone loss
12
mechanical
11
complications
10
complications hip
8

Similar Publications

Background: The paratenon has been shown to promote Achilles tendon healing, but the evidence supporting the role of paratenon protection technique in Achilles tendon repair is sparse. We retrospectively assessed the results of a paratenon-sparing repair technique vs an open giftbox repair of Achilles tendon ruptures.

Methods: Patients with Achilles tendon rupture who underwent surgical treatment at our hospital between January 2015 and August 2021 were retrospectively reviewed.

View Article and Find Full Text PDF

Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.

Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.

View Article and Find Full Text PDF

Background: Despite the physiological advantages of positive end-expiratory pressure (PEEP), its optimal utilization during one-lung ventilation (OLV) remains uncertain. We aimed to investigate whether individualized PEEP titration by lung compliance is associated with a reduced risk of postoperative pulmonary complications during OLV.

Methods: We searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials until April 1, 2024, to identify published randomized controlled trials that compared individualized PEEP titration by lung compliance with fixed PEEP during OLV.

View Article and Find Full Text PDF

Background: Post-stroke epilepsy (PSE) is a major complication of stroke. However, data about the predictors of PSE in patients with acute ischemic stroke (AIS) undergoing mechanical thrombectomy are limited.

Objective: To evaluate the relationship between intraoperative angiographic signs and PSE risk in patients with anterior circulation AIS who underwent mechanical thrombectomy.

View Article and Find Full Text PDF

ECLS-SHOCK and DanGer Shock: Implications for optimal temporary mechanical circulatory support use for cardiogenic shock due to acute myocardial infarction.

Can J Cardiol

January 2025

University of Montreal Hospital Center (CHUM) Cardiovascular Center & Research Center (CRCHUM), University of Montreal, Montreal, Quebec, Canada. Electronic address:

Despite concerted efforts to rapidly identify patients with cardiogenic shock complicating acute myocardial infarction (AMI-CS) and provide timely revascularization, early mortality remains stubbornly high. While artificially augmenting systemic flow through the use of temporary mechanical circulatory support (tMCS) devices would be expected to reduce the rate of progression to multi-organ dysfunction and thereby enhance survival, reliable evidence for benefit has remained elusive with lingering questions regarding the appropriate selection of both patients and devices, as well as the timing of device implantation relative to other critical interventions. Further complicating matters are the resource-intensive multidisciplinary systems of care that must be brought to bear in this complex patient population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!