  • The study compares the safety and accuracy of three methods for placing pedicle screws in scoliosis surgery: robotic navigation, O-arm-based navigation, and freehand techniques.
  • Results showed that the robotic navigation technique had the highest accuracy for screw placement (94.7% during operation and 96.7% postoperatively), while the freehand method had the lowest accuracy (80.4%).
  • Although the robotic and O-arm methods were more accurate, they took longer to complete than the freehand technique, with no significant differences in blood loss or hospital stay among the groups.

Article Abstract

Purpose: To compare the safety and accuracy of cannulated pedicle screw placement using a robotic-navigation technique, O-arm-based navigation technique, or freehand technique.

Methods: This study analyzed 106 consecutive patients who underwent scoliosis surgery. Thirty-two patients underwent robotic-navigation-assisted pedicle screw insertion (Group 1), 34 patients underwent O-arm-based navigation-guided pedicle screw insertion (Group 2), and 40 patients underwent freehand pedicle screw insertion (Group 3). The primary outcome measure was the accuracy of screw placement. Secondary outcome parameters included operation time, blood loss, radiation exposure, and postoperative stay.

Results: A total of 2035 cannulated pedicle screws were implanted in 106 patients. The accuracy rate of the first pedicle screw placement during operation was significantly greater in Group 1 (94.7%) than in Group 2 (89.2%; P < 0.001). The accuracy rate of pedicle screw placement postoperatively decreased in the order of Group 1 (96.7%) > Group 2 (93.0%) > Group 3 (80.4%; P < 0.01). There were no significant differences in blood loss or postoperative stay among the three groups (P > 0.05). The operation times of Group 1 and Group 2 were significantly longer than that of Group 3 (P < 0.05).

Conclusion: The robotic-navigation and O-arm-based navigation techniques effectively increased the accuracy and safety of pedicle screw insertion alternative to the freehand technique in scoliosis surgery. Compared with the O-arm-based navigation technique, the robotic-navigation technique increases the mean operation time, but also increases the accuracy of pedicle screw placement. A three-dimensional scan after insertion of the K-wire may increase the accuracy of pedicle screw placement in the O-arm-based navigation technique.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00586-023-07710-8DOI Listing

Publication Analysis

Top Keywords

pedicle screw
24
screw placement
16
patients underwent
16
cannulated pedicle
12
screw insertion
12
insertion group
12
safety accuracy
8
accuracy cannulated
8
scoliosis surgery
8
o-arm-based navigation
8

Similar Publications

Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.

Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.

View Article and Find Full Text PDF

Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.

Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.

View Article and Find Full Text PDF

Study Design: Narrative Review.

Objective: The management of spinal tumors requires a multi-disciplinary approach including surgery, radiation, and systemic therapy. Surgical approaches typically require posterior segmental instrumentation to maintain long-term spinal stability.

View Article and Find Full Text PDF

3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.

View Article and Find Full Text PDF

Introduction: Congenital lumbar kyphosis is present in about 15% of patients with myelomeningocele. Worsening of deformity with complications such as chronic skin ulcers and bone exposure is common. In patients under 8 years of age, treatment becomes even more challenging: in addition to resecting the apex of the kyphotic deformity, we should ideally stabilize the spine with fixation methods that do not interrupt the growth of the rib cage, associated with the challenging pelvic fixation in this population.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!