The proof-of-concept of an integrated automatic foam microextraction lab-in-syringe (FME-LIS) platform coupled to high performance liquid chromatography is presented. Three different sol-gel coated foams were synthesized, characterized, and conveniently packed inside the glass barrel of the LIS syringe pump, as an alternative approach for sample preparation, preconcentration and separation. The proposed system efficiently combines the inherent benefits of lab-in-syringe technique, the good features of sol-gel sorbents, the versatile nature of foams/sponges, as well as the advantages of automatic systems. Bisphenol A (BPA) was used as model analyte, due to the increasing concern for the migration of this compound from household containers. The main parameters that affect the extraction performance of the system were optimized and the proposed method was validated. The limit of detection for BPA were 0.5 and 2.9 μg L, for a sample volume of 50 mL and 10 mL, respectively. The intra-day precision was <4.7% and the inter-day precision was <5.1% in all cases. The performance of the proposed methodology was evaluated for the migration studies of BPA using different food simulants, as well as for the analysis of drinking water. Good method applicability was observed based on the relative recovery studies (93-103%).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2023.341400DOI Listing

Publication Analysis

Top Keywords

integrated automatic
8
sol-gel coated
8
foam microextraction
8
high performance
8
performance liquid
8
liquid chromatography
8
automatic lab-in-syringe
4
lab-in-syringe sol-gel
4
coated foam
4
microextraction platform
4

Similar Publications

The optimal color space enables advantageous smartphone-based colorimetric sensing.

Biosens Bioelectron

December 2024

Biophotonic Nanosensors Laboratory, Centro de Física Aplicada y Tecnología Avanzada (CFATA), Universidad Nacional Autónoma de México (UNAM), Querétaro, 76230, Mexico. Electronic address:

Smartphone-based colorimetric (bio)sensing is a promising alternative to conventional detection equipment for on-site testing, but it is often limited by sensitivity to lighting conditions. These issues are usually avoided using housings with fixed light sources, increasing the cost and complexity of the on-site test, where simplicity, portability, and affordability are a priority. In this study, we demonstrate that careful optimization of color space can significantly boost the performance of smartphone-based colorimetric sensing, enabling housing-free, illumination-invariant detection.

View Article and Find Full Text PDF

MultiTax-human: an extensive and high-resolution human-related full-length 16S rRNA reference database and taxonomy.

Microbiol Spectr

January 2025

State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, National Clinical Research Center for Infectious Diseases, National Medical Center for Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Considering that the human microbiota plays a critical role in health and disease, an accurate and high-resolution taxonomic classification is thus essential for meaningful microbiome analysis. In this study, we developed an automatic system, named MultiTax pipeline, for generating taxonomy from full-length 16S rRNA sequences using the Genome Taxonomy Database and other existing reference databases. We first constructed the MultiTax-human database, a high-resolution resource specifically designed for human microbiome research and clinical applications.

View Article and Find Full Text PDF

Introduction: The Virginia Memory Project (VMP) is a statewide epidemiological registry for Alzheimer's disease and related disorders (ADRD) and other neurodegenerative conditions. It aims to support dementia research, policy, and care by leveraging the Centers for Disease Control (CDC) Healthy Brain Initiative (HBI) Roadmap.

Methods: To capture comprehensive data, the VMP integrates self-enrollment and automatic enrollment using Virginia's All-Payer Claims Database (APCD).

View Article and Find Full Text PDF

Identifying driver genes in cancer is a difficult task because of the heterogeneity of cancer as well as the complex interactions among genes. As sequencing data become more readily available, there is a growing need for detecting cancer driver genes based on statistical and mathematical modeling methods. Currently, plenty of driver gene identification algorithms have been published, but they fail to achieve consistent results.

View Article and Find Full Text PDF

In regular biosample cryopreservation operations, dropwise pipetting and continuous swirling are ordinarily needed to prevent cell damage ( sudden osmotic change, toxicity and dissolution heat) caused by the high-concentration cryoprotectant (CPA) addition process. The following CPA removal process after freezing and rewarming also requires multiple sample transfer processes and manual work. In order to optimize the cryopreservation process, especially for trace sample preservation, here we present a microfluidic approach integrating CPA addition, sample storage, CPA removal and sample resuspension processes on a 30 × 30 × 4 mm three-layer chip.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!