Background: A major concern among health care experts is a shortage of N95 filtering facepiece respirators during a pandemic. If the supply of N95 filtering facepiece respirators becomes limited, reusable elastomeric half-mask respirators (EHMRs) may be used to protect health care workers. The focus of this study was to evaluate the effects on the filter performance of wiping decontamination for EHMR P100 filter cartridges.

Methods: The filter cartridge exterior of EHMR Honeywell, Moldex, and Mine Safety Appliance (MSA) models was wiped using quaternary ammonium and sodium hypochlorite wipes. These filter cartridge properties were assessed including observational analysis and filter performance tests. These wiping and assessing procedures were repeated after each set of wiping cycles (50, 100, 150, 200, and 400 cycles) to determine the effects of wiping decontamination.

Results: For sodium hypochlorite wipes, Honeywell, Moldex, and MSA models passed the National Institute for Occupational Safety and Health (NIOSH) liquid particulate penetration criteria for all wiping cycles from 50 to 400 (penetrations<0.014%). For quaternary ammonium wipes, filter penetrations of Moldex failed (penetrations>0.03%) after 150 cycles, while the filter penetrations of Honeywell and MSA passed for all wiping cycles (penetrations ≤0.013%).

Conclusions: Wiping decontamination methods using sodium hypochlorite and quaternary ammonium wipes could be considered promising decontamination candidates for Honeywell, Moldex, and MSA reuse, except for the wiping number selection for Moldex (<150 cycles) when using the quaternary ammonium wipe.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajic.2023.05.013DOI Listing

Publication Analysis

Top Keywords

wiping decontamination
12
honeywell moldex
12
sodium hypochlorite
12
wiping cycles
12
wiping
9
effects wiping
8
elastomeric half-mask
8
half-mask respirators
8
respirators ehmrs
8
n95 filtering
8

Similar Publications

Reusing healing abutments is common practice among clinicians; however, ensuring complete surface decontamination is crucial to avoid further complications. This study aimed to evaluate the cleaning potential of Er: YAG laser at different frequencies, as an adjunctive step prior to autoclave sterilization. Forty contaminated healing abutments were divided into four groups.

View Article and Find Full Text PDF

Removal efficiency of antineoplastic drug cyclophosphamide by hypochlorous acid.

J Occup Environ Hyg

December 2024

Department of Pharmacy, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.

Hypochlorous acid (HClO), one of the major reactive oxygen species, is obtained by electrolyzing a sodium chloride solution. HClO is a safe and effective disinfectant and decomposing agent widely used as an alternative to sodium hypochlorite (NaClO). In this study, the authors aimed to evaluate the safety and efficiency of HClO generated by electrolyzing sodium chloride as a decontaminant.

View Article and Find Full Text PDF

Firefighter occupational exposures were categorized as a class 1 (known) carcinogen by the International Agency for Research on Cancer in 2022. As a result, firefighters have become heavily focused on identifying effective and easy to implement decontamination strategies to reduce their chemical exposures. Skin decontamination using wipes post-exposure is one decontamination strategy that every firefighter has available to them.

View Article and Find Full Text PDF

[Not Available].

Can J Hosp Pharm

October 2024

, B. Pharm., M. Sc., M.B.A., F.C.S.H.P., F.O.P.Q., est responsable, Unité de recherche en pratique pharmaceutique, CHU Sainte-Justine, et professeur titulaire de clinique, Faculté de pharmacie, Université de Montréal (Québec).

Background: The arms of chairs in outpatient oncology clinics are frequently contaminated with cyclophosphamide.

Objective: To evaluate the effectiveness of decontamination scenarios.

Methods: This was a descriptive simulation-type study of 6 decontamination scenarios of a silicone fabric surface contaminated with 10 μg of cyclophosphamide.

View Article and Find Full Text PDF

Introduction: Throughout surgical and invasive procedures, reusable instruments and flexible endoscopes become soiled with organic and inorganic materials. When these substances are permitted to dry, a matrix of microbial cells, called biofilm, forms on the surface of devices, irreversibly binding and subsequently impeding the disinfection and sterilization process. To prevent biofilm formation from occurring, devices must be continuously flushed and wiped with water throughout the procedure and at the end of the case.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!