Comparative analysis of signal accuracy of three SpO monitors during motion and low perfusion conditions.

J Clin Monit Comput

Patient Care Solutions, GE HealthCare, Teollisuuskatu 29, 00510, Helsinki, Finland.

Published: December 2023

To compare pulse oximetry performance during simulated conditions of motion and low perfusion in three commercially available devices: GE HealthCare CARESCAPE ONE TruSignal SpO Parameter, Masimo RADICAL-7 and Medtronic Nellcor PM1000N. After IRB approval, 28 healthy adult volunteers were randomly assigned to the motion group (N = 14) or low perfusion (N = 14) group. Pulse oximeters were placed on the test and control hands using random assignment of digits 2-5. Each subject served as their own control through the series of repeated pair-wise measurements. Reference co-oximetry oxyhemoglobin (SaO) measurements from the radial artery were also obtained in the motion group. SpO readings were compared between the test and control hands in both groups and to SaO measurements in the motion group. Accuracy was assessed through testing of accuracy root-mean squared (ARMS) and mean bias. In the simulated motion test group the overall Accuracy Root Mean Square (ARMS) versus SaO was 1.88 (GE), 1.79 (Masimo) and 2.40 (Nellcor), with overall mean bias of - 0.21 (Masimo), 0.45 (GE), and 0.78 (Nellcor). In the motion hand, ARMS versus SaO was 2.45 (GE), 3.19 (Masimo) and 4.15 (Nellcor), with overall mean bias of - 0.75 (Masimo), - 0.01 (GE), and 0.04 (Nellcor). In the low perfusion test group, ARMS versus the control hand SpO for low PI was 3.24 (GE), 3.48 (Nellcor) and 4.76 (Masimo), with overall bias measurements of - 0.53 (Nellcor), 0.96 (GE) and 1.76 (Masimo). Experimental results for all tested devices met pulse oximetry regulatory and testing standards requirements. Overall, SpO device performance across the three devices in this study was similar under both motion and low perfusion conditions. SpO measurement accuracy degraded for all three devices during motion as compared to non-motion. Accuracy also degraded during normal to low, very low, or ultra low perfusion and was more pronounced compared to the changes observed during simulated motion. While some statistically significant differences in individual measurements were found, the clinical relevance of these differences requires further study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10651546PMC
http://dx.doi.org/10.1007/s10877-023-01029-xDOI Listing

Publication Analysis

Top Keywords

low perfusion
24
motion low
12
motion group
12
arms versus
12
motion
10
low
9
perfusion conditions
8
pulse oximetry
8
test control
8
control hands
8

Similar Publications

The effect of a new thinking guidance of OPACCUS for shock on the 30-day mortality: A multicenter, prospective, observational, cohort study.

Eur J Intern Med

December 2024

Department of Critical Care Medicine, West China Hospital, Sichuan University, Chengdu, PR China. Electronic address:

Objectives: The purpose of this study was to determine whether our new thinking guidance named OPACCUS (oxygen metabolism, perfusion, arterial tension, cardiac output, systemic congestion, unregulated host response and search for inciting illness event) with 7 questions you need to ask before shock therapy and evidences provided by critical ultrasound considering hemodynamics, the unregulated host response and inciting illness event would improve mortality in shock patients.

Design: A multicenter, prospective, observational cohort study.

Setting: Intensive care units of 20 hospitals in Southwest China.

View Article and Find Full Text PDF

Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.

Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.

View Article and Find Full Text PDF

Objectives: Blood pressure (BP) management is challenging in patients with acute ischemic supratentorial stroke undergoing recanalization therapy due to the lack of established guidelines. Assessing dynamic cerebral autoregulation (dCA) may address this need, as it is a bedside technique that evaluates the transfer function phase in the very low-frequency (VLF) range (0.02-0.

View Article and Find Full Text PDF

Objective: To investigate the incidence and survival rates of paediatric patients receiving resuscitation for in-hospital cardiac arrest (IHCA) in a teaching hospital in Northern Jordan, comparing initial pulseless rhythms and bradycardia rhythm with poor perfusion.

Design: Retrospective observational study SETTING: An university-affiliated tertiary hospital in Northern Jordan, covering January 2015 to December 2022.

Patients: All hospitalised paediatric patients aged 1 month-18 years who received cardiopulmonary resuscitation (CPR) for cardiac arrest were included in the study.

View Article and Find Full Text PDF

Metronomic chemotherapy (MCT) is a novel chemotherapy approach characterized by a high-frequency, low-dose administration strategy. The "chemo-switch" regimen involves the sequential use of two dosing strategies: maximum tolerated dose (MTD) chemotherapy and MCT. For patients with pancreatic ductal adenocarcinoma (PDAC), selecting novel chemotherapy regimens appropriately according to their physical conditions may help address the challenges associated with MTD chemotherapy, such as excessive toxicity, prolonged tumor recovery, and suboptimal efficacy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!