Objective: Lipoprotein(a) (Lp[a]) and the atherogenic index of plasma (AIP) have been reported as predictive markers of coronary artery calcium (CAC). However, previous studies demonstrated that the cardiovascular risk associations with Lp(a) are attenuated in patients with low-density lipoprotein cholesterol (LDL-C) levels ≤135 mg/dL. However, few articles have identified the risk factors of CAC in patients without high LDL-C. Therefore, we performed this study to investigate the association of Lp(a) and AIP with CAC in patients with LDL-C levels ≤135 mg/dL.
Methods: This study included 625 lipid-lowering agent naive patients with LDL-C levels ≤135 mg/dL who underwent coronary computed tomographic angiography. We performed multivariate logistic regression analysis to evaluate the risk factors for a coronary artery calcium score (CACS) >0, CACS ≥400, and CAC ≥90th percentile.
Results: The mean age of the patients was 55.0±7.9 years and their mean LDL-C level was 94.7 ±23.3 mg/dL. Multivariate regression analysis showed that age, male sex, diabetes, hypertension, Lp(a), and AIP were independent predictors of CAS>0. Age, male sex, and diabetes were independent predictors of CACS≥400. Diabetes, hypertension, and AIP were independent predictors of CAC ≥90th percentile (all <0.05). Unlike Lp(a), higher AIP tertiles were associated with significantly higher CAC percentiles and greater proportions of patients with CACS ≥400 and CAC ≥90th percentile.
Conclusion: In patients without high LDL-C, AIP could be a more reliable predictor of CAC than Lp(a).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10232225 | PMC |
http://dx.doi.org/10.12997/jla.2023.12.2.152 | DOI Listing |
Cardiovasc Eng Technol
January 2025
Transonic Systems Inc., 34 Dutch Mill Road, Ithaca, New York, 14850, USA.
Purpose: Over time, transit time flow measurement (TTFM) has proven itself as a simple and effective tool for intra-operative evaluation of coronary artery bypass grafts (CABGs). However, metrics used to screen for possible technical error show considerable spread, preventing the definition of sharp cut-off values to distinguish between patent, questionable, and failed grafts. The simulation study presented in this paper aims to quantify this uncertainty for commonly used patency metrics, and to identify the most important physiological parameters influencing it.
View Article and Find Full Text PDFHerz
January 2025
Faculty of Medicine, Department of Cardiology, Bilecik Şeyh Edebali University, Pelitözü Mahallesi Fatih Sultan Mehmet Blv. No. 27 Merkez, Bilecik, Turkey.
Background: The aim of this study was to compare the efficacy outcomes of the traditional Judkins left and right catheters with those of the recently introduced Tiger catheter in female participants aged 65 years and older who underwent transradial coronary angiography.
Methods: A cohort of 160 female patients aged 65 and older who were scheduled for coronary angiography (CAG) were divided into two groups according to the use of Tiger (n = 80) or Judkins (n = 80) catheters for radial angiography at a ratio of 1:1, respectively. We analyzed the effectiveness of the Tiger and Judkins catheters, the incidence of catheter failure, contrast volume, CAG time, fluoroscopy time, dose-area product (in mGy/cm), and the occurrence of radial spasm.
J Cardiothorac Vasc Anesth
December 2024
Penn State Milton S. Hershey Medical Center, Hershey, PA.
Cardiovasc Revasc Med
December 2024
Department of Cardiology, Tel Aviv Sourasky Medical Center, affiliated with the School of Medicine, Tel Aviv University, Israel.
Background: Angina with non-obstructive coronary artery disease (ANOCA) is commonly observed in patients with stable angina undergoing coronary angiography. Current guidelines recommend non-invasive stress testing as the first step in diagnosing coronary microvascular disease (CMD). This study aims to evaluate the diagnostic value of non-invasive stress testing in patients invasively diagnosed with CMD.
View Article and Find Full Text PDFJ Mol Cell Cardiol
December 2024
A.I.Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland; Heart Centre and Gene Therapy Unit, Kuopio University Hospital, Kuopio, Finland. Electronic address:
Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!