Balance disorders are highly prevalent worldwide, causing substantial disability with high personal and socioeconomic impact. The prognosis in many of these patients is poor, and rehabilitation programs provide little help in many cases. This medical problem can be addressed using microelectronics by combining the highly successful cochlear implant experience to produce a vestibular prosthesis, using the technical advances in micro gyroscopes and micro accelerometers, which are the electronic equivalents of the semicircular canals (SCC) and the otolithic organs. Reaching this technological milestone fostered the possibility of using these electronic devices to substitute the vestibular function, mainly for visual stability and posture, in case of damage to the vestibular endorgans. The development of implantable and non-implantable devices showed diverse outcomes when considering the integrity of the vestibular pathways, the device parameters (current intensity, impedance, and waveform), and the targeted physiological function (balance and gaze). In this review, we will examine the development and testing of various prototypes of the vestibular implant (VI). The insight raised by examining the state-of-the-art vestibular prosthesis will facilitate the development of new device-development strategies and discuss the feasibility of complex combinations of implantable devices for disorders that directly affect balance and motor performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10230114 | PMC |
http://dx.doi.org/10.3389/fnint.2023.1161860 | DOI Listing |
J Periodontol
January 2025
Department of Biomedical and Neuromotor Sciences, School of Dentistry - Division of Periodontology and Implantology, Alma Mater Studiorum - University of Bologna, Bologna, Italy.
Background: Crown cementation is a common technique for implant-supported prosthodontics. However, for possible slipping of the cement below the mucosal margin, its thorough removal poses some issues. The objective of this study was to evaluate the presence of submucosal cement residues in patients with peri-implant disease by endoscopic visualization and to investigate the potential correlation between the pathological scenario and the spatial position of cement residues.
View Article and Find Full Text PDFJ Otolaryngol Head Neck Surg
January 2025
Division of Otorhinolaryngology-Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, University of Geneva, Geneva, Switzerland.
Background: A vestibular implant can partially restore vestibular function by providing motion information through implanted electrodes. During vestibular implantation, various obstructions of the semicircular canals, such as protein deposits, fibrosis, and ossification, can be encountered. The objective was to explore the relationship between preoperative imaging and intraoperative findings of semicircular canal obstruction and to develop surgical strategies for dealing with obstructions of the semicircular canal(s) in patients eligible for vestibular implantation.
View Article and Find Full Text PDFElife
December 2024
Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, United States.
The vestibular system is integral to behavior; the loss of peripheral vestibular function leads to disabling consequences, such as blurred vision, dizziness, and unstable posture, severely limiting activities of daily living. Fortunately, the vestibular system's well-defined peripheral structure and well-understood encoding strategies offer unique opportunities for developing sensory prostheses to restore vestibular function. While these devices show promising results in both animal models and implanted patients, substantial room for improvement remains.
View Article and Find Full Text PDFOtol Neurotol
January 2025
Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, MN.
Objective: To compare the utility of intraoperative electrically evoked auditory brainstem response (eABR) and electrically evoked stapedial reflex testing (eSRT) for cochlear nerve integrity monitoring during simultaneous translabyrinthine resection of vestibular schwannoma (VS) and cochlear implantation.
Study Design: Historical cohort study.
Setting: Tertiary academic referral center.
Eur Ann Otorhinolaryngol Head Neck Dis
December 2024
Service d'ORL et de chirurgie cervico-faciale, centre hospitalo-universitaire, Dijon, France; Laboratoire ICMUB, UMR CNRS 6302, université de Bourgogne, Dijon, France.
Aim: To evaluate the audiometric results of tympanoplasty with stapedectomy and insertion of a synthetic total ossicular replacement prosthesis (TORP).
Material And Methods: Retrospective observational study conducted on a cohort of 15 patients (16 ears) aged 10 to 58 years (mean: 36 years) with chronic otitis media (COM) and tympanosclerosis (n=9), stapediovestibular ankylosis (n=3), minor aplasia (n=3) or post-traumatic ossicular dislocation (n=1). Treatment consisted in tympanoplasty with stapedectomy and TORP placement by the same operator, between December 1, 2012 and January 30, 2023, in a French university hospital department, with follow-up ranging from 2 to 92 months (mean: 24 months).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!