AI Article Synopsis

  • * In a randomized trial with 439 participants, researchers compared two groups: one using these bioimpedance readings and a control group without.
  • * Results showed no significant difference in RKF decline or blood pressure between groups, indicating that following a standardized fluid assessment protocol suffices for preserving RKF, making bioimpedance measurements unnecessary.

Article Abstract

Avoiding excessive dialysis-associated volume depletion may help preserve residual kidney function (RKF). To establish whether knowledge of the estimated normally hydrated weight from bioimpedance measurements (BI-NHW) when setting the post-hemodialysis target weight (TW) might mitigate rate of loss of RKF, we undertook an open label, randomized controlled trial in incident patients receiving HD, with clinicians and patients blinded to bioimpedance readings in controls. A total of 439 patients with over 500 ml urine/day or residual GFR exceeding 3 ml/min/1.73m were recruited from 34 United Kingdom centers and randomized 1:1, stratified by center. Fluid assessments were made for up to 24 months using a standardized proforma in both groups, supplemented by availability of BI-NHW in the intervention group. Primary outcome was time to anuria, analyzed using competing-risk survival models adjusted for baseline characteristics, by intention to treat. Secondary outcomes included rate of RKF decline (mean urea and creatinine clearance), blood pressure and patient-reported outcomes. There were no group differences in cause-specific hazard rates of anuria (0.751; 95% confidence interval (0.459, 1.229)) or sub-distribution hazard rates (0.742 (0.453, 1.215)). RKF decline was markedly slower than anticipated, pooled linear rates in year 1: -0.178 (-0.196, -0.159)), year 2: -0.061 (-0.086, -0.036)) ml/min/1.73m/month. Blood pressure and patient-reported outcomes did not differ by group. The mean difference agreement between TW and BI-NHW was similar for both groups, Bioimpedance: -0.04 kg; Control: -0.25 kg. Thus, use of a standardized clinical protocol for fluid assessment when setting TW is associated with excellent preservation of RKF. Hence, bioimpedance measurements are not necessary to achieve this.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.kint.2023.05.016DOI Listing

Publication Analysis

Top Keywords

residual kidney
8
kidney function
8
randomized controlled
8
controlled trial
8
bioimpedance measurements
8
rkf decline
8
blood pressure
8
pressure patient-reported
8
patient-reported outcomes
8
hazard rates
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!