In this work, a narrow-linewidth polarization-maintaining (PM) all-fiber amplifier with near-diffraction-limited beam quality and record output power is presented. First, a 4.45-kW PM fiber amplifier with a 3-dB linewidth of 0.08 nm and root mean square (rms) linewidth of 0.22 nm is achieved based on optimized phase modulation. However, the sideband of the spectrum broadens significantly during the amplification process, which is mainly caused by the additional intensity variation of the injected signal. Meanwhile, an up to 5.04-kW linearly polarized fiber laser with a relatively stable spectral bandwidth is achieved by effectively suppressing spectral broadening. At the maximum output power, the rms linewidth is 0.2 nm, the beam quality factor M is less than 1.3, the polarization extinction ratio (PER) is 16.5 dB, and the signal-to-noise ratio (SNR) is approximately 53 dB. The further power scaling of the amplifier is mainly limited by the pump power. To the best of our knowledge, this is the maximum output power of a narrow linewidth linearly polarized fiber amplifier to date.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.489289DOI Listing

Publication Analysis

Top Keywords

output power
16
linearly polarized
12
polarized fiber
12
fiber amplifier
12
beam quality
12
narrow linewidth
8
record output
8
near-diffraction-limited beam
8
rms linewidth
8
maximum output
8

Similar Publications

1D moisture-enabled electric generators (MEGs) hold great promise for powering electronic textiles, but their current limitations in power output and operational duration restrict their application in wearable technology. This study introduces a high-performance yarn-based moisture-enabled electric generator (YMEG), which comprises a carbon-fiber core, a cotton yarn active layer with a radial gradient of poly(4-styrensulfonic acid) and poly(vinyl alcohol) (PSSA/PVA), and an aluminum wire as the outer electrode. The unique design maintains a persistent moisture gradient between the interior and exterior electrodes, enhancing performance through the continuous proton diffusion from PSSA and Al⁺ ions from the aluminum wire.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to examine the sex-specific influence of expected exercise duration on the physiological responses to RPE-clamp exercise anchored to RPE 15 with participants being deceived into believing the RPE-clamp exercise would last for 20-, 30-, or 40-min, but all trials were 30-min.

Methods: Twelve males and 12 females completed a graded exercise test followed by randomly ordered RPE-clamp trials at RPE15 on the Borg 6-20 scale where subjects were deceived into expecting exercise to last for either 20-, 30-, or 40-min, but the actual duration for each trial was 30-min. Separate 2 (Sex [Male vs.

View Article and Find Full Text PDF

The microgrid (MG) faces significant security issues due to the two-way power and information flow. Integrating an Energy Management System (EMS) to balance energy supply and demand in Malaysian microgrids, this study designs a Fuzzy Logic Controller (FLC) that considers intermittent renewable sources and fluctuating demand patterns. FLC offers a flexible solution to energy scheduling effectively assessed by MATLAB/Simulink simulations.

View Article and Find Full Text PDF

This study explores the optimization and performance of a hybrid energy system combining a geothermal heat pump (GHP) with a wind turbine in Izmir, Turkey. Utilizing a 4E (Energy, Exergy, Economic, and Exergoenvironmental) analysis approach, the system aims to enhance winter heating efficiency. Geothermal heat pumps leverage the Earth's consistent temperatures for heating and cooling, offering a sustainable alternative to traditional energy sources.

View Article and Find Full Text PDF

Prototype analysis of a low-power, small-scale wearable medical device.

J Electr Bioimpedance

January 2024

Electrical Engineering Department, State University of Santa Catarina, Santa Catarina, Brazil.

Wearable and portable devices are gaining significant popularity across consumer electronics as well as in medical and industrial fields. To ensure that these devices are both comfortable and appealing to users, they need to have low battery consumption and be compact in both size and weight. The EGluco project is focused on developing a wearable device for non-invasive blood glucose monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!