A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement Repeatability and Reproducibility of Virtual Goniometry of a Set of Acquired Images in Youths with Arthrogryposis Multiplex Congenita. | LitMetric

Objectives: To evaluate the intra-rater repeatability and the inter-rater reproducibility of using a virtual goniometer to measure upper and lower extremity joint range of motion (ROM) in youths with arthrogryposis multiplex congenita (AMC).

Methods: Youths presenting with AMC aged 8 to 21 years old were recruited. ROM of the upper and lower limbs were assessed remotely during a teleassessment on a video-conferencing platform. Screen captures were taken and ROM were measured by two raters, two-weeks apart, using a virtual goniometer. Intraclass correlation coefficient (ICC) and associated 95% confidence interval (CI) were calculated to assess intra-and inter-rater repeatability and reproducibility.

Results: Nine participants were included with a median age of 15.9 years (range: 11.3 to 20.8 years). The overall intra-rater ICC was 0.997 (95% CI:0.996 to 0.997) for the first rater and 0.993 (95% CI:0.992 to 0.994) for the second rater. The inter-rater ICC ranged from 0.410 (95% CI:-0.392; 0.753) for forearm pronation to 0.998 (95% CI:0.996; 0.999) for elbow flexion.

Conclusions: Results of the current study suggest that virtual goniometry is reproducible and repeatable for the ROM of most joints. Future studies should evaluate procedural reliability and validity of the proposed method for youth with complex conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233227PMC

Publication Analysis

Top Keywords

reproducibility virtual
8
virtual goniometry
8
youths arthrogryposis
8
arthrogryposis multiplex
8
multiplex congenita
8
virtual goniometer
8
upper lower
8
95% ci0996
8
95%
5
measurement repeatability
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!