A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of appropriate needle length considering skin thickness with the real injection posture for insulin injections in diabetic patients. | LitMetric

Background: Insulin treatment is widely used not only for type 1 but also for type 2 diabetes patients. Insulin must be injected into the subcutaneous tissue to be effective. The needle length has been shortened for safety and efficiency. However, whether patients use an appropriate needle length is unclear.

Methods: Skin thickness was measured by ultrasound with patients in their usual posture during injection. Furthermore, the effect of the intervention in which the needle length was changed was investigated.

Results: Thirty-eight percent of the patients had fluid leakage and injected the needle intradermally. The average skin thickness was 3.3 mm while sitting, which was greater than that in a previous report including measurements taken while lying down. Consequently, the skin thickness was > 4 mm in 9.5% of the patients who used 4-mm needles. Cases of leakage and intradermal injection decreased when the needle length was changed.

Conclusions: This study identified that the needle length should be considered in patients with thick skin or a lower body mass index due to possibility of intradermal injection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233969PMC
http://dx.doi.org/10.1186/s40780-023-00288-9DOI Listing

Publication Analysis

Top Keywords

needle length
24
skin thickness
16
appropriate needle
8
intradermal injection
8
needle
7
patients
7
length
6
skin
5
investigation appropriate
4
length considering
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!