A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of Acetabular Screws on the Initial Stability of Porous Coated Acetabular Implants in Revision Total Hip Arthroplasty. | LitMetric

Introduction: Revision total hip arthroplasty in the setting of acetabular bone loss remains a challenging clinical entity. Deficiencies of the acetabular rim, walls, and/or columns may limit the bony surface area and initial acetabular construct stability necessary for osseointegration of cementless components. Press-fit acetabular components with supplemental acetabular screw fixation represent a common technique aimed to minimize implant micromotion and allow for definitive osseointegration. Although acetabular screw fixation is commonly practiced in revision hip arthroplasty, few studies to date have examined the screw properties associated with maximal acetabular construct stability. The purpose of the present report is to examine acetabular screw fixation in a pelvis model mimicking Paprosky IIB acetabular bone loss.

Methods: Measuring bone-implant interface micromotion as a surrogate for initial implant stability, experimental models assessed the effect of screw number, screw length, and screw position on construct stability subject to a cyclic loading protocol designed to replicate joint reaction forces of two common daily activities.

Results: Trends towards increasing stability were demonstrated with increasing screw number, increasing screw length, and concentrating screws in the supra-acetabular dome. All experimental constructs yielded micromotion levels sufficient for bone ingrowth, except when screws in the dome were moved to the pubis and ischium.

Conclusions: When using a porous coated revision acetabular implant to treat Paprosky IIB defects, screws should be used, and furthermore, increasing number, length, and position within the acetabular dome may help further stabilize the construct.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10225166PMC
http://dx.doi.org/10.7759/cureus.38257DOI Listing

Publication Analysis

Top Keywords

acetabular
12
hip arthroplasty
12
construct stability
12
acetabular screw
12
screw fixation
12
screw
9
porous coated
8
revision total
8
total hip
8
acetabular bone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!