Is there a Difference in Interfragmentary Compression Strength Between Fully or Partially Threaded Screws? Results of an Experimental Biomechanical Pilot Study.

Rev Bras Ortop (Sao Paulo)

Instituto de Saúde de Berlim em Charité - Universidade de Medicina de Berlim, Instituto Julius Wolff de Biomecânica e Regeneração Musculoesquelética, Berlim, Alemanha.

Published: April 2023

 This study assessed differences between fully- and partially-threaded screws in the initial interfragmentary compression strength. Our hypothesis was that there would be an increased loss in initial compression strength with the partially-threaded screw.  A 45-degree oblique fracture line was created in artificial bone samples. The first group (FULL,  = 6) was fixed using a 3.5-mm fully-threaded lag screw, while the second group (PARTIAL,  = 6) used a 3.5-mm partially-threaded lag screw. Torsional stiffness for both rotational directions were evaluated. The groups were compared based on biomechanical parameters: angle-moment-stiffness, time-moment-stiffness, maximal torsional moment (failure load), and calibrated compression force based on pressure sensor measurement.  After loss of one PARTIAL sample, no statistically significant differences in calibrated compression force measurement were observed between both groups: [median (interquartile range)] FULL: 112.6 (10.5) N versus PARTIAL: 106.9 (7.1) N, Mann-Whitney U-test:  = 0.8). In addition, after exclusion of 3 samples for mechanical testing (FULL  = 5, PARTIAL  = 4), no statistically significant differences were observed between FULL and PARTIAL constructs in angle-moment-stiffness, time-moment-stiffness, nor maximum torsional moment (failure load).  There is no apparent difference in the initial compression strength (compression force or construct stiffness or failure load) achieved using either fully- or partially-threaded screws in this biomechanical model in high-density artificial bone. Fully-threaded screws could, therefore, be more useful in diaphyseal fracture treatment. Further research on the impact in softer osteoporotic, or metaphyseal bone models, and to evaluate the clinical significance is required.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10212624PMC
http://dx.doi.org/10.1055/s-0042-1750828DOI Listing

Publication Analysis

Top Keywords

compression strength
16
failure load
12
compression force
12
interfragmentary compression
8
fully- partially-threaded
8
partially-threaded screws
8
initial compression
8
artificial bone
8
lag screw
8
angle-moment-stiffness time-moment-stiffness
8