Objectives: The design of tibial trays for total knee arthroplasty (TKA) has been a topic of research for several decades. Although all-polyethylene trays were developed to address issues such as osteolysis and to enhance the longevity of the prosthesis, as well as knee range of motion, metal-backed designs have remained the most commonly used type of prosthesis. This meta-analysis aimed to compare the clinical, radiological, and survival outcomes of both designs.

Methods: Five databases were searched from inception until October 1, 2020, for randomized controlled trials (RCTs) that compared the outcomes of all-polyethylene and metal-backed tibial components in TKA. The outcomes of interest included range of motion, knee society score, stairs climbing scores, radiostereographic analysis, survivorship and complication. This review was conducted in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Risk of bias was assessed using the Newcastle-Ottawa tool.

Results: A total of 14 RCTs with 1367 TKA were included with a mean age of - years and - years for all-polyethylene and metal-backed tibial components groups, respectively. All-polyethylene group demonstrated statistically significant differences in five-year survivorship (OR 0.27; 95% CI 0.10-0.75; p value 0.01) and stairs climbing score (OR - 2.07; 95% CI - 3.27-0.87; p value 0.0007) when compared to the metal-backed group. The metal-backed design was significantly more radiographically stable in anterior-posterior, varus-valgus, and internal-external rotations at the 2-year follow-up compared to all-polyethylene tibias (OR - 0.09; 95% CI - 0.16 to - 0.02; p value 0.02) as per the pooled radiostereographic analysis. However, ten-year survivorship (OR 0.92; 95% CI 0.53-1.60; p value 0.78), range of motion (OR - 0.57; 95% CI - 2.00-0.85, p value 0.43), knee society scores (OR 1.38; 95% CI - 0.47-3.23, p value 0.14), and complications (OR 0.83; 95% CI 0.5-1.39, p value 0.48) were comparable between both groups.

Conclusions: While this meta-analysis suggests that all-polyethylene tibial components in total knee arthroplasty may offer advantages over metal-backed components in terms of five-year survivorship, and stairs climbing score, this finding should be considered in the context of potential confounding factors. Nonetheless, based on the results, the all-polyethylene implant should be considered a viable choice for primary knee replacement.

Level Of Evidence: I.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10651551PMC
http://dx.doi.org/10.1007/s00590-023-03594-yDOI Listing

Publication Analysis

Top Keywords

tibial components
16
metal-backed tibial
12
total knee
12
knee arthroplasty
12
range motion
12
stairs climbing
12
all-polyethylene
8
components total
8
randomized controlled
8
controlled trials
8

Similar Publications

Purpose: To clarify the influence of biomechanics on post-operative clinical outcomes in bicruciate-retaining total knee arthroplasty (BCR-TKA).

Methods: Severe medial osteoarthritis who underwent BCR-TKA were examined. Each patient was asked to perform a squat (weight-bearing [WB]) and active assisted knee flexion (non-WB [NWB]) under single fluoroscopy surveillance.

View Article and Find Full Text PDF

Purpose The infrapatellar fat pad (IFP) has the lowest pain threshold among all knee joint components and causes anterior knee pain after knee arthroplasty. It has been reported that selective muscle atrophy of the vastus medialis (VM) and fibrosis of the IFP may develop following knee joint surgery. Ultrasound enables visualization of IFP deformation (A1) from within the joint to the proximal area in response to muscle contraction, and this may be helpful in developing preventive and therapeutic strategies for IFP fibrosis.

View Article and Find Full Text PDF

Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.

View Article and Find Full Text PDF

: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated.

View Article and Find Full Text PDF

Background: Many patients with a lower limb socket-suspended prothesis experience socket-related problems, such as pain, chronic skin conditions, and mechanical problems, and as a result, health-related quality of life (HRQoL) is often negatively affected. A bone-anchored prosthesis can overcome these problems and improve HRQoL, but these prostheses have potential downsides as well. A valid and reliable tool to assess potential candidates for surgery concerning a favorable risk-benefit ratio between potential complications related to bone-anchored prostheses and improvements in HRQoL is not available yet.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!