Background: In soccer, the day of the week with the highest external load is match day (MD), with starters (>60 minutes per match) showing higher levels of physical fitness and seasonal high-intensity loading. It is necessary, therefore, to determine training strategies to reduce the differences between starters and nonstarters. The aim of this study was to analyze and compare the external load of different training compensatory strategies with match external load in female nonstarters.

Hypothesis: A strategy combining small-sided games (SSG) and running-based drills (RBD) would reproduce match demands, with RBD leading to greater high-intensity running and SSG leading to a greater number of accelerations and decelerations.

Study Design: Descriptive and comparative study.

Level Of Evidence: Level 4.

Methods: The training and match external load of 14 female players belonging to the same reserve squad of a Spanish First Division Club (Liga Reto Iberdrola) was registered. In the first session after the match (MD+1), nonstarters (<60 minutes in the match) performed 1 of 3 different compensatory strategies: RBD, SSG, or a mixed intervention combining the previous strategies (RBD+SSG). Starters carried out a recovery session.

Results: A marked difference in load was observed between the compensatory training strategies and MD. In comparison with MD, RBD showed greater high-intensity and sprint distances and lower acceleration, SSG showed less high-intensity running and sprint distances, lower peak velocity, and greater acceleration, and RBD+SSG registered lower accelerations. In addition, nonstarters covered greater high-intensity running and sprint distances in RBD and achieved higher accelerations in SSG.

Conclusion: RBD and SSG compensatory strategies could be recommended to nonstarter female soccer players in MD+1 to compensate for match external load deficits.

Clinical Relevance: This study provides comprehensive information on the compensatory exercises of female soccer players, which can be useful for strength and conditioning coaches when developing recovery strategies during a microcycle.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10606965PMC
http://dx.doi.org/10.1177/19417381231176555DOI Listing

Publication Analysis

Top Keywords

external load
16
load female
12
compensatory strategies
8
match external
8
leading greater
8
match
6
load
5
nonstarter compensatory
4
training
4
strategies training
4

Similar Publications

Objective: : The purpose of this study was to characterize the dynamic distribution of training loads in a kettlebell program and evaluate its effects on muscle strength and aerobic capacity.

Methods: Fourteen recreationally active women with no kettlebell training experience (age: 25.86 ± 5.

View Article and Find Full Text PDF

Recent advances in centrifugal microfluidics for point-of-care testing.

Lab Chip

January 2025

The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.

Point-of-care testing (POCT) holds significant importance in the field of infectious disease prevention and control, as well as personalized precision medicine. The emerging microfluidics, capable of minimal reagent consumption, integration, and a high degree of automation, play a pivotal role in POCT. Centrifugal microfluidics, also termed lab-on-a-disc (LOAD), is a significant subfield of microfluidics that integrates crucial analytical steps onto a single chip, thereby optimizing the process and enabling high-throughput, automated analysis.

View Article and Find Full Text PDF

Mechanosensitive stacking structure with continuous solar controllability for real-time thermal management.

Mater Horiz

January 2025

State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan 430200, China.

Adaptive control of solar light based on an optical switching strategy is essential to tune thermal gain, while real-time solar regulation and hence on-demand thermal management coupled with dynamic conditions still faces a formidable challenge. Herein, we develop a stacking structure which is mechanosensitive and can be finely tuned depending on the dynamic cavitation effect. Specifically, the stacking structure transfers from a solid monolith state to porous layered state progressively under mechanical stretching, and the resulting porous layered state gradually goes back to the solid monolith state once the load is released.

View Article and Find Full Text PDF

Several microtechnology devices quantify the external load of team sports using Global Positioning Systems sampling at 5, 10, or 15 Hz. However, for short, explosive actions, such as collisions, these sample rates may be limiting. It is known that very high-frequency sampling is capable of capturing changes in actions over a short period of time.

View Article and Find Full Text PDF

Influence of Freeze-Thaw Cycles and Sustained Load on the Durability and Bearing Capacity of Reinforced Concrete Columns.

Materials (Basel)

December 2024

Ruicheng Construction Engineering Co., Ltd., Lianyungang 222042, China.

The deterioration of concrete structures is mainly due to the combined action of the environment and external load. In this study, 32 reinforced concrete columns were prepared to evaluate the coupling actions on the properties of reinforced concrete structures. The durability, bearing capacity, and failure mode of reinforced concrete columns were investigated under the combined action of freeze-thaw (F-T) cycles, sustained load, and salt corrosion (water or composite salt solution).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!