Background: In soccer, the day of the week with the highest external load is match day (MD), with starters (>60 minutes per match) showing higher levels of physical fitness and seasonal high-intensity loading. It is necessary, therefore, to determine training strategies to reduce the differences between starters and nonstarters. The aim of this study was to analyze and compare the external load of different training compensatory strategies with match external load in female nonstarters.
Hypothesis: A strategy combining small-sided games (SSG) and running-based drills (RBD) would reproduce match demands, with RBD leading to greater high-intensity running and SSG leading to a greater number of accelerations and decelerations.
Study Design: Descriptive and comparative study.
Level Of Evidence: Level 4.
Methods: The training and match external load of 14 female players belonging to the same reserve squad of a Spanish First Division Club (Liga Reto Iberdrola) was registered. In the first session after the match (MD+1), nonstarters (<60 minutes in the match) performed 1 of 3 different compensatory strategies: RBD, SSG, or a mixed intervention combining the previous strategies (RBD+SSG). Starters carried out a recovery session.
Results: A marked difference in load was observed between the compensatory training strategies and MD. In comparison with MD, RBD showed greater high-intensity and sprint distances and lower acceleration, SSG showed less high-intensity running and sprint distances, lower peak velocity, and greater acceleration, and RBD+SSG registered lower accelerations. In addition, nonstarters covered greater high-intensity running and sprint distances in RBD and achieved higher accelerations in SSG.
Conclusion: RBD and SSG compensatory strategies could be recommended to nonstarter female soccer players in MD+1 to compensate for match external load deficits.
Clinical Relevance: This study provides comprehensive information on the compensatory exercises of female soccer players, which can be useful for strength and conditioning coaches when developing recovery strategies during a microcycle.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10606965 | PMC |
http://dx.doi.org/10.1177/19417381231176555 | DOI Listing |
J Chiropr Med
December 2024
Department of Sports, Postgraduate Program in Physical Education, Federal University of Espirito Santo, Vitoria, Espirito Santo, Brazil.
Objective: : The purpose of this study was to characterize the dynamic distribution of training loads in a kettlebell program and evaluate its effects on muscle strength and aerobic capacity.
Methods: Fourteen recreationally active women with no kettlebell training experience (age: 25.86 ± 5.
Lab Chip
January 2025
The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.
Point-of-care testing (POCT) holds significant importance in the field of infectious disease prevention and control, as well as personalized precision medicine. The emerging microfluidics, capable of minimal reagent consumption, integration, and a high degree of automation, play a pivotal role in POCT. Centrifugal microfluidics, also termed lab-on-a-disc (LOAD), is a significant subfield of microfluidics that integrates crucial analytical steps onto a single chip, thereby optimizing the process and enabling high-throughput, automated analysis.
View Article and Find Full Text PDFMater Horiz
January 2025
State Key Laboratory of New Textile Materials and Advanced Processing Technologies, Wuhan Textile University, Wuhan 430200, China.
Adaptive control of solar light based on an optical switching strategy is essential to tune thermal gain, while real-time solar regulation and hence on-demand thermal management coupled with dynamic conditions still faces a formidable challenge. Herein, we develop a stacking structure which is mechanosensitive and can be finely tuned depending on the dynamic cavitation effect. Specifically, the stacking structure transfers from a solid monolith state to porous layered state progressively under mechanical stretching, and the resulting porous layered state gradually goes back to the solid monolith state once the load is released.
View Article and Find Full Text PDFSensors (Basel)
December 2024
National Institute of Physical Education of Catalonia (INEFC), 08038 Barcelona, Spain.
Several microtechnology devices quantify the external load of team sports using Global Positioning Systems sampling at 5, 10, or 15 Hz. However, for short, explosive actions, such as collisions, these sample rates may be limiting. It is known that very high-frequency sampling is capable of capturing changes in actions over a short period of time.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Ruicheng Construction Engineering Co., Ltd., Lianyungang 222042, China.
The deterioration of concrete structures is mainly due to the combined action of the environment and external load. In this study, 32 reinforced concrete columns were prepared to evaluate the coupling actions on the properties of reinforced concrete structures. The durability, bearing capacity, and failure mode of reinforced concrete columns were investigated under the combined action of freeze-thaw (F-T) cycles, sustained load, and salt corrosion (water or composite salt solution).