A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative zoom lens calibration for high magnification surgical microscope. | LitMetric

Intraoperative zoom lens calibration for high magnification surgical microscope.

Comput Methods Programs Biomed

Department of Robotics and Mechatronics Engineering, DGIST, 333 Techno Jungang-Daero, Daegu 42988, Republic of Korea. Electronic address:

Published: August 2023

Background And Objectives: An augmented reality (AR)-based surgical guidance system is often used with high-magnification zoom lens systems such as a surgical microscope, particularly in neurology or otolaryngology. To superimpose the internal structures of relevant organs on the microscopy image, an accurate calibration process to obtain the camera intrinsic and hand-eye parameters of the microscope is essential. However, conventional calibration methods are unsuitable for surgical microscopes because of their narrow depth of focus at high magnifications. To realize AR-based surgical guidance with a high-magnification surgical microscope, we herein propose a new calibration method that is applicable to the highest magnification levels as well as low magnifications.

Methods: The key idea of the proposed method is to find the relationship between the focal length and the hand-eye parameters, which remains constant regardless of the magnification level. Based on this, even if the magnification changes arbitrarily during surgery, the intrinsic and hand-eye parameters are recalculated quickly and accurately with one or two pictures of the pattern. We also developed a dedicated calibration tool with a prism to take focused pattern images without interfering with the surgery.

Results: The proposed calibration method ensured an AR error of < 1 mm for all magnification levels. In addition, the variation of focal length was within 1% regardless of the magnification level, and the corresponding variation with the conventional calibration method exceeded 20% at high magnification levels.

Conclusions: The comparative study showed that the proposed method has outstanding accuracy and reproducibility for a high-magnification surgical microscope. The proposed calibration method is applicable to various endoscope or microscope systems with zoom lens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2023.107618DOI Listing

Publication Analysis

Top Keywords

surgical microscope
16
calibration method
16
zoom lens
12
hand-eye parameters
12
calibration
8
high magnification
8
ar-based surgical
8
surgical guidance
8
intrinsic hand-eye
8
conventional calibration
8