Synthetic aperture (SA) can be used for both anatomic and functional imaging, where tissue motion and blood velocity are revealed. Often, sequences optimized for anatomic B-mode imaging are different from functional sequences, as the best distribution and number of emissions are different. B-mode sequences demand many emissions for a high contrast, whereas flow sequences demand short sequences for high correlations yielding accurate velocity estimates. This article hypothesizes that a single, universal sequence can be developed for linear array SA imaging. This sequence yields high-quality linear and nonlinear B-mode images as well as accurate motion and flow estimates for high and low blood velocities and super-resolution images. Interleaved sequences with positive and negative pulse emissions for the same spherical virtual source were used to enable flow estimation for high velocities and make continuous long acquisitions for low-velocity estimation. An optimized pulse inversion (PI) sequence with 2 ×12 virtual sources was implemented for four different linear array probes connected to either a Verasonics Vantage 256 scanner or the SARUS experimental scanner. The virtual sources were evenly distributed over the whole aperture and permuted in emission order for making flow estimation possible using 4, 8, or 12 virtual sources. The frame rate was 208 Hz for fully independent images for a pulse repetition frequency of 5 kHz, and recursive imaging yielded 5000 images per second. Data were acquired from a phantom mimicking the carotid artery with pulsating flow and the kidney of a Sprague-Dawley rat. Examples include anatomic high contrast B-mode, non-linear B-mode, tissue motion, power Doppler, color flow mapping (CFM), vector velocity imaging, and super-resolution imaging (SRI) derived from the same dataset and demonstrate that all imaging modes can be shown retrospectively and quantitative data derived from it.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2023.3280803 | DOI Listing |
BMC Med Educ
January 2025
First Affiliated Hospital of Kunming Medical University, No. 295, Xichang Road, Kunming, 650032, China.
Background: With the continuous development of educational methods, desktop virtual reality technology has gradually attracted widespread attention. Although current research has shown that this technology can promote learning among nursing students, the mechanism and intrinsic factors are not yet clear. This study aims to explore the mechanisms and factors of the application of desktop virtual reality technology in nursing students' education and discuss the possible outcomes.
View Article and Find Full Text PDFEnviron Int
January 2025
State Key Laboratory of Marine Pollution and Department of Chemistry, City University of Hong Kong, Hong Kong 999077, China; Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Hong Kong 999077, China.
Despite the ubiquity and complexity of atmospheric polycyclic aromatic compounds (PACs), many of these compounds are largely unknown and lack sufficient toxicity data for comprehensive risk assessments. In this study, nontarget screening assisted by in-house and self-developed spectra databases was, therefore, employed to identify PACs in atmospheric particulate matter collected from multiple outdoor settings. Additionally, absorption, distribution, metabolism, excretion, and toxicity properties were evaluated to indicate PAC's overall abilities to cause adverse outcomes and incorporated into a novel health risk assessment model to assess their inhalation risks.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Indian J Thorac Cardiovasc Surg
February 2025
Department of Paediatric and Congenital Heart Surgery, Kokilaben Dhirubhai Ambani Hospital and Medical Research Institute, Rao Saheb, Achutrao Patwardhan Marg, Four Bungalows, Andheri West, Mumbai, Maharashtra 400053 India.
Unlabelled: In congenital heart surgery, redo-sternotomies are very common. In most cases, sternal re-entry is achieved without serious complications. However, sometimes elective institution of peripheral cardiopulmonary bypass is needed for safe sternotomy, albeit with a long cardio-pulmonary bypass time.
View Article and Find Full Text PDFArch Rehabil Res Clin Transl
December 2024
Division of Pediatric Rehabilitation Medicine, Department of Pediatrics, University of Alabama at Birmingham, Birmingham, AL.
Objective: To analyze existing literature on virtual exercise interventions delivered to people with disabilities to assess effectiveness, efficiency, usability, satisfaction, and feasibility, and describe current trends that aimed to improve health outcomes among people with disabilities.
Data Sources: CINAHL, MEDLINE, and PsycINFO were searched.
Study Selection: Articles were included if they were (1) incorporated a virtual exercise intervention including people with physical disabilities and mobility limitations aged 18 years and older and (2) published between the years of 2009-August 14, 2024 with free access to full-text, peer-reviewed papers; and (3) published in English.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!