Gaussian Processes for real-time 3D motion and uncertainty estimation during MR-guided radiotherapy.

Med Image Anal

Department of Radiotherapy, Division of Imaging & Oncology, University Medical Center Utrecht, The Netherlands; Computational Imaging Group for MR diagnostics & therapy, Center for Image Sciences, University Medical Center Utrecht, The Netherlands.

Published: August 2023

Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed hybrid MR-linac scanner holds the promise to efficiently deal with such respiratory motion through real-time adaptive MR-guided radiotherapy (MRgRT). For MRgRT, motion-fields should be estimated from MR-data and the radiotherapy plan should be adapted in real-time according to the estimated motion-fields. All of this should be performed with a total latency of maximally 200 ms, including data acquisition and reconstruction. A measure of confidence in such estimated motion-fields is highly desirable, for instance to ensure the patient's safety in case of unexpected and undesirable motion. In this work, we propose a framework based on Gaussian Processes to infer 3D motion-fields and uncertainty maps in real-time from only three readouts of MR-data. We demonstrated an inference frame rate up to 69 Hz including data acquisition and reconstruction, thereby exploiting the limited amount of required MR-data. Additionally, we designed a rejection criterion based on the motion-field uncertainty maps to demonstrate the framework's potential for quality assurance. The framework was validated in silico and in vivo on healthy volunteer data (n=5) acquired using an MR-linac, thereby taking into account different breathing patterns and controlled bulk motion. Results indicate end-point-errors with a 75th percentile below 1 mm in silico, and a correct detection of erroneous motion estimates with the rejection criterion. Altogether, the results show the potential of the framework for application in real-time MR-guided radiotherapy with an MR-linac.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.media.2023.102843DOI Listing

Publication Analysis

Top Keywords

mr-guided radiotherapy
12
gaussian processes
8
respiratory motion
8
estimated motion-fields
8
including data
8
data acquisition
8
acquisition reconstruction
8
uncertainty maps
8
rejection criterion
8
motion
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!