Clinically useful finite element models of the natural ankle - A review.

Clin Biomech (Bristol)

Department of Mechanical Engineering, University of Bath, Bath, UK. Electronic address:

Published: June 2023

Background: Biomechanical simulation of the foot and ankle complex is a growing research area but compared to simulation of joints such as hip and knee, it has been under investigated and lacks consistency in research methodology. The methodology is variable, data is heterogenous and there are no clear output criteria. Therefore, it is very difficult to correlate clinically and draw meaningful inferences.

Methods: The focus of this review is finite element simulation of the native ankle joint and we will explore: the different research questions asked, the model designs used, ways the model rigour has been ensured, the different output parameters of interest and the clinical impact and relevance of these studies.

Findings: The 72 published studies explored in this review demonstrate wide variability in approach. Many studies demonstrated a preference for simplicity when representing different tissues, with the majority using linear isotropic material properties to represent the bone, cartilage and ligaments; this allows the models to be complex in another way such as to include more bones or complex loading. Most studies were validated against experimental or in vivo data, but a large proportion (40%) of studies were not validated at all, which is an area of concern.

Interpretation: Finite element simulation of the ankle shows promise as a clinical tool for improving outcomes. Standardisation of model creation and standardisation of reporting would increase trust, and enable independent validation, through which successful clinical application of the research could be realised.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2023.106006DOI Listing

Publication Analysis

Top Keywords

finite element
12
element simulation
8
studies validated
8
clinically finite
4
element models
4
models natural
4
ankle
4
natural ankle
4
ankle review
4
review background
4

Similar Publications

Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes.

World J Orthop

January 2025

Undip Biomechanics Engineering and Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia.

Total hip arthroplasty for adults with sequelae from childhood hip disorders poses significant challenges due to altered anatomy. The paper published by Oommen reviews the essential management strategies for these complex cases. This article explores the integration of finite element analysis (FEA) to enhance surgical precision and outcomes.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the effects of attachment design on maxillary molar distalization and simultaneous expansion during distalization, and the influence of third molars on distalization in the clear aligner technique using the finite element method.

Methods: Six models were created to evaluate three different attachment designs on the second molars. Model I: employed a vertical rectangular attachment; Model II: used a vertical rectangular attachment with the presence of the third molar; Model III: used a combined semi-elliptical attachment; and Model IV: featured an opposed semi-elliptical attachment with buccal and palatal components.

View Article and Find Full Text PDF

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis.

Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm-thick aligners and horizontal attachments, were integrated into the software.

View Article and Find Full Text PDF

Background And Objectives: Bennett fractures are intra-articular fractures of the first metacarpal, typically resulting from axial loading. The optimal surgical method for fixation remains a topic of ongoing debate. This study aims to evaluate and compare the biomechanical properties of different fixation techniques.

View Article and Find Full Text PDF

In this study, a method for predicting the thermal shock life of coatings is proposed, and a model for predicting the thermal shock life of coatings based on high temperature thermal shock life test and three-dimensional heat transfer analysis is established. Firstly, the thermal shock life of coatings at different cooling and heating cycle temperatures is obtained through a designed thermal shock life testing device for silicide coatings at a wide-temperature range from 500℃ to 3000℃. Secondly, the actual thickness of the coating and the continuous oxidation in the thermal shock life test are taken into consideration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!