Objectives: We investigated the predictive value of aortic valve cusp retraction, calcification, and fenestration for aortic valvuloplasty feasibility.

Methods: Multicenter data were collected for 2082 patients who underwent surgical aortic valvuloplasty or aortic valve replacement. The study population had retraction, calcification, or fenestration in at least one aortic valve cusp. Controls had normal or prolapsed cusps.

Results: All cusp characteristics demonstrated significantly increased odds ratios [ORs] for switch to valve replacement. This effect was strongest for cusp retraction, followed by calcification and fenestration (OR, 25.14; P ≤ .001; OR, 13.50, P ≤ .001; OR, 12.32, P ≤ .001). Calcification and retraction displayed increased odds for developing grade 4 aortic regurgitation compared with grade 0 or 1 combined on average over time (OR, 6.67; P ≤ .001; OR, 4.13; P = .038). Patients with cusp retraction showed increased risk for reintervention at 1- and 2-year follow-up after aortic valvuloplasty (hazard ratio, 5.66; P ≤ .001; hazard ratio, 3.22, P = .007). Cusp fenestration was the only group showing neither an increased risk of postoperative severe aortic regurgitation (P = .57) or early reintervention (P = .88) compared with the control group.

Conclusions: Aortic valve cusp retraction, calcification, and fenestration were all related to increased rates of switch to valve replacement. Calcification and retraction were associated with recurrence of severe aortic regurgitation. Retraction was related to early reintervention. Fenestration was neither associated with recurrence of severe aortic regurgitation or reintervention. This indicates that surgeons are well able to distinguish aortic valve repair candidates in patients with cusp fenestration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2023.05.020DOI Listing

Publication Analysis

Top Keywords

aortic valve
28
retraction calcification
20
calcification fenestration
20
≤ 001
20
valve cusp
16
cusp retraction
16
aortic regurgitation
16
aortic
14
aortic valvuloplasty
12
valve replacement
12

Similar Publications

A Novel Staging System of Cardiac Damage in Aortic Stenosis based on Multi-Chamber Myocardial Deformation.

Eur Heart J Cardiovasc Imaging

January 2025

Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Aims: This study evaluates whether multi-chamber myocardial deformation analysis using speckle tracking echocardiography (STE) can enhance validated current staging systems and improve risk stratification for patients with moderate-to-severe aortic stenosis (AS).

Methods And Results: We reanalyzed 2D, Doppler, and STE data obtained from two cohorts: derivation (654 patients, median age: 82 years; 51% men) and validation (237 patients, median age: 77 years; 55% men) with at least moderate AS (aortic valve area<1.5 cm2).

View Article and Find Full Text PDF

Objectives: The Ross procedure for aortic regurgitation (AR) and abnormal aortic valve morphologies is associated with an increased risk of autograft dilatation. Autograft support may ameliorate this problem. We analyzed the results for all haemodynamic lesions and the effect of autograft support.

View Article and Find Full Text PDF

Re-sheathing failure with Navitor during transcatheter aortic valve implantation: a case report.

Eur Heart J Case Rep

January 2025

The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.

Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.

Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.

View Article and Find Full Text PDF

Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!