Purpose: The aim of this study was to compare five different neuroretinal rim (NRR) measurement methods, based on quadrants and NRR widths, in the assessment of the ISNT (inferior (I) > superior (S) > nasal (N) > temporal (T)) rule, and its variants IST (inferior (I) > superior (S) > temporal (S)) rule, IS (inferior (I) > superior (S)) rule and T (temporal is the thinnest) rule in a normal population. Factors influencing compliance with this rule and its variants were also evaluated.

Methods: Stereoscopic fundus images were analysed through a dichoptic viewing system. Two graders labelled the optic disc and cup, as well as the fovea. Custom-made software automatically determined the limits of the optic disc and cup and examined the ISNT rule and its variants using several NRR measurement methods.

Results: Sixty-nine subjects with normal eyes were enrolled. For the various NRR measuring methods, the percentage of eyes following the rules, that is, validity ranges were 0.0%-15.9% for the ISNT rule, 31.9%-59.4% for the IST rule, 46.4%-59.4% for the IS rule and 50.7%-100.0% for the T rule. Significant intra-measurement agreement ranges were IST (κ = 0.50-0.85), IS (κ = 0.68-1.00) and T (κ = 0.24-0.77). Only the IST and IS rules achieved significant inter-measurement agreement (κ = 0.47-1.00). After multivariate and receiver operating characteristic (ROC) curve analyses, the vertical cup position cup (area under the ROC curve (AUROC) = 0.60-0.96; cut-off = |0.005|) was the most important predictor for virtually all NRR measurement agreements for the ISNT, IST and IS rules. The horizontal cup position (AUROC = 0.50-0.92; cut-off = -0.028 to 0.05) was the most important predictive factor for the majority of the NRR measurement agreements for the T rule.

Conclusions: Only the IST and IS rules are valid for the same normal subjects. The most important factor affecting the validity of the ISNT rule and its variants was the anatomical cup position. NRR measurement agreements based on NRR quadrants exhibited larger validity and better agreement. The IST and IS rules can be combined with the alternative SIT (superior (S) > inferior (I) > temporal (T)) and SI (superior (S) > inferior (I)) rules to detect almost all normal subjects.

Download full-text PDF

Source
http://dx.doi.org/10.1111/opo.13171DOI Listing

Publication Analysis

Top Keywords

rule variants
20
nrr measurement
20
isnt rule
16
ist rules
16
rule
12
inferior i > superior
12
cup position
12
measurement agreements
12
measuring methods
8
normal population
8

Similar Publications

Background: There are no approved oral disease-modifying treatments for Alzheimer's disease (AD).

Objectives: The objective of this study was to assess efficacy and safety of blarcamesine (ANAVEX®2-73), an orally available small-molecule activator of the sigma-1 receptor (SIGMAR1) in early AD through restoration of cellular homeostasis including autophagy enhancement.

Design: ANAVEX2-73-AD-004 was a randomized, double-blind, placebo-controlled, 48-week Phase IIb/III trial.

View Article and Find Full Text PDF

Replicator dynamics on heterogeneous networks.

J Math Biol

January 2025

Laboratory of Mathematics and Complex Systems, Ministry of Education, School of Mathematical Sciences, Beijing Normal University, Beijing, People's Republic of China.

Networked evolutionary game theory is a well-established framework for modeling the evolution of social behavior in structured populations. Most of the existing studies in this field have focused on 2-strategy games on heterogeneous networks or n-strategy games on regular networks. In this paper, we consider n-strategy games on arbitrary networks under the pairwise comparison updating rule.

View Article and Find Full Text PDF

An Intrinsic Characterization of Shannon's and Rényi's Entropy.

Entropy (Basel)

December 2024

Institute of Mathematics, University of Mannheim, 68131 Mannheim, Germany.

All characterizations of the Shannon entropy include the so-called chain rule, a formula on a hierarchically structured probability distribution, which is based on at least two elementary distributions. We show that the chain rule can be split into two natural components, the well-known additivity of the entropy in case of cross-products and a variant of the chain rule that involves only a single elementary distribution. The latter is given as a proportionality relation and, hence, allows a vague interpretation as self-similarity, hence intrinsic property of the Shannon entropy.

View Article and Find Full Text PDF

Fatal familial insomnia: A new case description with response to thoracic sympathetic nerve thermocoagulation and stellate ganglion block.

Sleep Med

December 2024

Department of Neurology, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Zhengzhou, Henan Province, China. Electronic address:

Fatal familial insomnia (FFI) is a rare autosomal dominant neurodegenerative disorder characterized by rapidly progressive dementia, severe sleep disturbances, and autonomic dysfunction. The clinical manifestations of FFI can exhibit substantial variations, making it crucial to rule out other conditions, such as autoimmune encephalitis and Creutzfeldt-Jakob disease, during early diagnosis. In this study, we describe the case of a 58-year-old man who experienced persistent insomnia, autonomic symptoms, gait instability, and rapidly progressive dementia.

View Article and Find Full Text PDF

ESR Essentials: diagnostic strategies in tinnitus-practice recommendations by the European Society of Head and Neck Radiology.

Eur Radiol

January 2025

Department of Radiological Sciences DSMC, University of Brescia, Radiology Unit 2, ASST Spedali Civili di Brescia, Brescia, Italy.

Article Synopsis
  • Tinnitus affects about 25% of older adults, with non-pulsatile tinnitus usually lacking structural causes, while pulsatile tinnitus may indicate underlying health issues that can be identified through imaging.
  • A thorough clinical evaluation is essential for determining the appropriate diagnostic strategy and imaging is warranted for unilateral non-pulsatile tinnitus or any pulsatile tinnitus cases.
  • Imaging methods like MRI or CT are used based on the type of tinnitus and any accompanying symptoms, with special attention needed for potential serious conditions in cases of pulsatile tinnitus.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!