A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improved Shear Strength Equation for Reinforced Concrete Columns Retrofitted with Hybrid Concrete Jackets. | LitMetric

Improved Shear Strength Equation for Reinforced Concrete Columns Retrofitted with Hybrid Concrete Jackets.

Materials (Basel)

Department of Architectural Engineering, Kyung Hee University, Deogyeong-Daero 1732, Yongin 17104, Republic of Korea.

Published: May 2023

The adequacy of retrofitting with concrete jacketing is influenced by the bonding between the old section and jacketing section. In this study, five specimens were fabricated, and cyclic loading tests were performed to investigate the integration behavior of the hybrid concrete jacketing method under combined loads. The experimental results showed that the strength of the proposed retrofitting method increased approximately three times compared to the old column, and bonding capacity was also improved. This paper proposed a shear strength equation that considers the slip between the jacketed section and the old section. Moreover, a factor was proposed for considering the reduction in the shear capacity of the stirrup resulting from the slippage between the mortar and stirrup utilized on the jacketing section. The accuracy and validity of the proposed equations were examined through a comparison with the ACI 318-19 design criteria and test results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221950PMC
http://dx.doi.org/10.3390/ma16103734DOI Listing

Publication Analysis

Top Keywords

shear strength
8
strength equation
8
hybrid concrete
8
concrete jacketing
8
improved shear
4
equation reinforced
4
concrete
4
reinforced concrete
4
concrete columns
4
columns retrofitted
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!