Corrosion Resistance and Titanium Ion Release of Hybrid Dental Implants.

Materials (Basel)

Bioengineering Institute of Technology, Facultad de Medicina y Ciencias de la Salud, Universidad Internacional de Catalunya, Josep Trueta s/n, Sant Cugat del Vallés, 08195 Barcelona, Spain.

Published: May 2023

One of the strategies for the fight against peri-implantitis is the fabrication of titanium dental implants with the part close to the neck without roughness. It is well known that roughness favors osseointegration but hinders the formation of biofilm. Implants with this type of structure are called hybrid dental implants, which sacrifice better coronal osseointegration for a smooth surface that hinders bacterial colonization. In this contribution, we have studied the corrosion resistance and the release of titanium ions to the medium of smooth (L), hybrid (H), and rough (R) dental implants. All implants were identical in design. Roughness was determined with an optical interferometer and residual stresses were determined for each surface by X-ray diffraction using the Bragg-Bentano technique. Corrosion studies were carried out with a Voltalab PGZ301 potentiostat, using Hank's solution as an electrolyte at a temperature of 37 °C. Open-circuit potentials (Eocp), corrosion potential (Ecorr), and current density (icorr) were determined. Implant surfaces were observed by JEOL 5410 scanning electron microscopy. Finally, for each of the different dental implants, the release of ions into Hank's solution at 37 °C at 1, 7, 14, and 30 days of immersion was determined by ICP-MS. The results, as expected, show a higher roughness of R with respect to L and compressive residual stresses of -201.2 MPa and -20.2 MPa, respectively. These differences in residual stresses create a potential difference in the H implant corresponding to Eocp of -186.4 mV higher than for the L and R of -200.9 and -192.2 mV, respectively. The corrosion potentials and current intensity are also higher for the H implants (-223 mV and 0.069 μA/mm) with respect to the L (-280 mV and 0.014 μA/mm and R (-273 mV and 0.019 μA/mm). Scanning electron microscopy revealed pitting in the interface zone of the H implants and no pitting in the L and R dental implants. The titanium ion release values to the medium are higher in the R implants due to their higher specific surface area compared to the H and L implants. The maximum values obtained are low, not exceeding 6 ppb in 30 days.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223376PMC
http://dx.doi.org/10.3390/ma16103650DOI Listing

Publication Analysis

Top Keywords

dental implants
24
implants
12
residual stresses
12
corrosion resistance
8
titanium ion
8
ion release
8
hybrid dental
8
hank's solution
8
scanning electron
8
electron microscopy
8

Similar Publications

Design: A triple-armed, double-blind randomized controlled trial with cross-over design investigated patient-reported satisfaction and objective dental evaluation of a 3-unit, monolithic zirconium dioxide (ZrO2), implant-supported fixed dental prosthesis (iFDP) fabricated with 2 completely digital workflows and 1 mixed analog-digital workflow.

Case Selection: Participants enrolled required rehabilitation of 2 dental implants in posterior region of either of the arches with a 3-unit, ZrO2 iFDP. A total of 20 participants received the 3 types of ZrO2, iFDP fabricated by 3 different methods.

View Article and Find Full Text PDF

Design: A retrospective cohort study assessing the mid-to-long-term outcomes and risk factors affecting the prosthetic success and survival of implant-supported cross-arch fixed dental prostheses (IFCDPs) with monolithic zirconia frameworks.

Cohort Selection: Forty-seven patients received a total of 51 cross-arch prostheses (27 maxillary and 24 mandibular prostheses), supported by 302 implants. Comprehensive clinical and radiographic records were available over a follow-up period ranging from 5 to 13 years.

View Article and Find Full Text PDF

Optimizing dental implant identification using deep learning leveraging artificial data.

Sci Rep

January 2025

Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Kagawa University, 1750-1, Ikenobe, Miki-cho, Kita-gun, Takamatsu, 761-0793, Kagawa, Japan.

This study aims to evaluate the potential enhancement in implant classification performance achieved by incorporating artificially generated images of commercially available products into a deep learning process of dental implant classification using panoramic X-ray images. To supplement an existing dataset of 7,946 in vivo dental implant images, a three-dimensional scanner was employed to create implant surface models. Subsequently, implant surface models were used to generate two-dimensional X-ray images, which were compiled along with original images to create a comprehensive dataset.

View Article and Find Full Text PDF

Objective: Peri-implant diseases (peri-implant mucositis and peri-implantitis) are inflammatory conditions that affect the peri-implant tissues and are induced by microbial biofilms (dental plaque) formed around the implant. Removal of biofilm is the fundamental step in managing peri-implant diseases. Interdental cleaning aids such as interdental brush, unitufted brush, or oral irrigation along with regular toothbrushing are recommended for effective plaque control around implants.

View Article and Find Full Text PDF

Titanium dioxide nanotube arrays (TNTs) generated in situ on the surface of dental implants have been shown to enhance bone integration for load-bearing support while managing load distribution and energy dissipation to prevent bone resorption from overload. However, their inadequate stability limits the clinical use of conventional TNTs. This study introduces an innovative approach to improve the mechanical stability of TNTs while maintaining their bone-integration efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!