Epitaxial SiC Dosimeters and Flux Monitoring Detectors for Proton Therapy Beams.

Materials (Basel)

Trento Institute for Fundamental Physics and Applications, National Institute of Nuclear Physics (TIFPA), Via Sommarive, 14, 38123 Povo, TN, Italy.

Published: May 2023

The exceptional optoelectronic properties and high radiation resistance of epitaxial silicon carbide make this material attractive for high-energy beam dosimetry and radiation monitoring, especially when strict requirements such as high signal-to-noise ratios, high time and spatial resolutions and low detectivity levels are required. A 4H-SiC Schottky diode has been characterized as a proton-flux-monitoring detector and dosimeter under proton beams for proton therapy. The diode was composed of an epitaxial film grown on 4H-SiC n-type substrate equipped with a gold Schottky contact. The diode was embedded in a tissue-equivalent epoxy resin and then characterized in terms of capacitance vs. voltage (C-V) and current vs. voltage (I-V) characteristics in the dark in the range of 0-40 V. The dark currents at room temperature are in the order of 1 pA, while the doping and active thicknesses extracted from the C-V are 2.5 × 10 cm and 2-4 μm, respectively. Proton beam tests have been carried out at the Proton Therapy Center of the Trento Institute for Fundamental Physics and Applications (TIFPA-INFN). They have been carried out with energies and extraction currents of 83-220 MeV and 1-10 nA, respectively, as typical for proton therapy applications, corresponding to dose rates in the range of 5 mGy/s to 2.7 Gy/s. The I-V characteristics measured under proton beam irradiation at the lowest dose rate showed a typical diode photocurrent response and a signal-to-noise ratio well above 10. Investigations with null bias evidenced a very good performance in terms of the diode's sensitivity, fast rise and decay times and response stability. The diode's sensitivity was in agreement with the expected theoretical values, and its response was linear throughout the whole investigated dose rate range.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223321PMC
http://dx.doi.org/10.3390/ma16103643DOI Listing

Publication Analysis

Top Keywords

proton therapy
16
i-v characteristics
8
proton beam
8
dose rate
8
diode's sensitivity
8
proton
7
epitaxial sic
4
sic dosimeters
4
dosimeters flux
4
flux monitoring
4

Similar Publications

Background: Locoregional external beam radiotherapy (EBRT) is selectively used in thyroid cancer patients to induce locoregional control. However, despite technological advances, EBRT remains associated with toxicities. We evaluated thyroid-cancer specific toxicities and long-term Quality of Life (QoL) post-EBRT.

View Article and Find Full Text PDF

Objective: To explore the current research status and trends of potassium-competitive acid blockers (P-CABs) in the treatment of acid related diseases (ARDs) using bibliometric analysis.

Materials And Methods: We collected publications related to P-CAB in the treatment of acid-related diseases in the Web of Science (WOS) Core Collection from the establishment of the database to 30 June 2024. We evaluated the publication volume and citation status over the years using the WOS platform, and visualized the authors, countries, institutions, keywords, and citations of the publications using CiteSpace and VOSviewer.

View Article and Find Full Text PDF

Prognostic Value of Pretreatment Carcinoembryonic Antigen (CEA) in Rectal Cancer Treated with Preoperative Short-Course Radiotherapy with Delayed Surgery or Long-Course Radiotherapy.

Onco Targets Ther

January 2025

Department of Radiation Oncology & Proton and Radiation Therapy Center, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung City, 833, Taiwan.

Purpose: To investigate the prognostic value of the pretreatment serum carcinoembryonic antigen (CEA) level in patients with rectal cancer treated by preoperative short-course radiotherapy (SCRT) followed by chemotherapy and delayed surgery.

Patients And Methods: Two hundred and sixty-six consecutive patients with locally advanced rectal adenocarcinoma without distant metastasis receiving preoperative radiotherapy were enrolled. Group 1 patients (n=144) received long-course radiotherapy (LCRT) with 50.

View Article and Find Full Text PDF

Background And Purpose: In proton therapy, a relative biological effectiveness (RBE) of 1.1 is used to convert proton dose into an equivalent photon dose. However, RBE varies with tissue type, fraction dose, and beam quality parameters beyond dose such as linear energy transfer (LET) raising concerns about increased local effectiveness and potential toxicity.

View Article and Find Full Text PDF

Proton pump inhibitors have been explored for potentiating cancer therapies via reverting the tumor acidity and promoting the activation of anti-tumor immune responses. To regulate the intracellular pH of melanoma and immunosuppressive myeloid cells, we developed poly(L-lactide-co-glycolide) nanoparticles loaded with esomeprazole (ESO-NPs). The effect of ESO-NPs on melanoma cells was observed as alkalinization and reduction of melanin content accompanied by a decrease of microphthalmia-associated transcription factor (MITF), poliovirus receptor (PVR), and programmed death ligand 1 (PD-L1) immune checkpoint expression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!