  • The study aimed to compare the actual range of motion (RoM) in patients who underwent reverse shoulder arthroplasty (RSA) to the virtual RoM predicted by preoperative planning software, particularly considering the role of the scapula-thoracic (ST) joint.
  • Results showed significant discrepancies in passive abduction and forward elevation between virtual and actual measurements, while external rotation with the arm at the side did not display a significant difference.
  • Measurement of angles revealed a significantly higher gleno-metaphyseal angle in actual assessments and a lower glenoid horizontal angle compared to the virtual planning, indicating notable variations in post-operative positioning.

Article Abstract

Introduction: The purpose of this study was to analyze the real range of motion (RoM) measured in patients operated on for reverse shoulder arthroplasty (RSA) and compare it to the virtual RoM provided by the preoperative planning software.

Hypothesis: There was a difference between virtual and real RoM, which can be explained by different factors, specifically the scapula-thoracic (ST) joint.

Methods: Twenty patients with RSA were assessed at a minimum follow-up of 18 months. Passive RoM in forward elevation abduction, without and with manually locking the ST joint, and in external rotation with arm at side were recorded. The humerus, scapula, and implants were manually segmented on post-operative CTs. Post-operative bony structures were registered to preoperative bony elements. From this registration, a post-operative plan corresponding to the real post-operative implant positioning was generated and the corresponding virtual RoM analysis was recorded. On the post-operative anteroposterior X-rays and 2D-CT coronal planning view, the glenoid horizontal line angle (GH), the metaphyseal horizontal line angle (MH), and the gleno-metaphyseal angle (GMA) were measured to assess the extrinsic glenoid inclination, as well as the relative position of the humeral and glenoid components.

Results: There were some significant differences between virtual and post-operative passive abduction and forward elevation, with (55° and 50°, < 0.0001) or without ST joint participation (15° and 27°, < 0.002). For external rotation with arm at side, there was no significant difference between planning (24° ± 26°) and post-operative clinical observation (19° ± 12°) ( = 0.38). For the angle measurements, the GMA was significantly higher (42.8° ± 15.2° vs. 29.1°± 18.2°, < 0.0001), and the GH angle, significantly lower on the virtual planning (85.2° ± 8.8° vs. 99.5° ± 12.5°, < 0.0001), while the MH was not different ( = 0.33).

Conclusions: The virtual RoM given by the planning software used in this study differs from the real post-operative passive RoM, except for external rotation. This can be explained by the lack of ST joint and soft tissues simulation. However, in focusing on the virtual GH participation, the simulation looks informative. Some modifications between the glenoid and humerus starting positions before running the motion analysis could be provided for making it more realistic and predictive of the RSA functional results.

Level Of Evidence: III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10219507PMC
http://dx.doi.org/10.3390/jpm13050765DOI Listing

Publication Analysis

Top Keywords

real post-operative
12
range motion
12
virtual rom
12
external rotation
12
virtual
8
reverse shoulder
8
shoulder arthroplasty
8
passive rom
8
forward elevation
8
rotation arm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!