A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanical Regulation of Oral Epithelial Barrier Function. | LitMetric

Mechanical Regulation of Oral Epithelial Barrier Function.

Bioengineering (Basel)

Department of Biochemistry and Molecular & Cellular Biology, School of Medicine, Georgetown University, Washington, DC 20057, USA.

Published: April 2023

Epithelial cell function is modulated by mechanical forces imparted by the extracellular environment. The transmission of forces onto the cytoskeleton by modalities such as mechanical stress and matrix stiffness is necessary to address by the development of new experimental models that permit finely tuned cell mechanical challenges. Herein, we developed an epithelial tissue culture model, named the 3D Oral Epi-mucosa platform, to investigate the role mechanical cues in the epithelial barrier. In this platform, low-level mechanical stress (0.1 kPa) is applied to oral keratinocytes, which lie on 3D fibrous collagen (Col) gels whose stiffness is modulated by different concentrations or the addition of other factors such as fibronectin (FN). Our results show that cells lying on intermediate Col (3 mg/mL; stiffness = 30 Pa) demonstrated lower epithelial leakiness compared with soft Col (1.5 mg/mL; stiffness = 10 Pa) and stiff Col (6 mg/mL; stiffness = 120 Pa) gels, indicating that stiffness modulates barrier function. In addition, the presence of FN reversed the barrier integrity by inhibiting the interepithelial interaction via E-cadherin and Zonula occludens-1. Overall, the 3D Oral Epi-mucosa platform, as a new in vitro system, will be utilized to identify new mechanisms and develop future targets involved in mucosal diseases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10215350PMC
http://dx.doi.org/10.3390/bioengineering10050517DOI Listing

Publication Analysis

Top Keywords

col mg/ml
12
mg/ml stiffness
12
epithelial barrier
8
barrier function
8
mechanical stress
8
oral epi-mucosa
8
epi-mucosa platform
8
mechanical
6
stiffness
6
epithelial
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!