Objective: To analyze and compare the clinical application value of three-dimensional reconstruction and computed tomography (CT)-guided Hook-wire localization for row lung segment resection of pulmonary nodules.
Methods: Retrospective analysis of the clinical data of 204 patients suffering from pulmonary nodules admitted to the Department of Thoracic Surgery of Gansu Provincial People's Hospital from June 2016 to December 2022. According to the preoperative positioning method, the group was divided into a 3D reconstruction group (98 cases) and a Hook-wire group (106 cases), respectively. The two groups of patients were propensity score matching (PSM) to compare their perioperative outcomes.
Results: All patients in both groups underwent successful surgeries without perioperative deaths. After PSM, 79 patients were successfully matched in each group. Two cases of pneumothorax, three cases of hemothorax, and four cases of decoupling occurred in the Hook-wire group; no complications of pneumothorax, hemothorax, and decoupling occurred in the 3D reconstruction group. Compared to the Hook-wire group, the 3D reconstruction group has shorter operative time (P = 0.001), less intraoperative bleeding (P < 0.001), less total postoperative chest drainage (P = 0.003), shorter postoperative tube placement time (P = 0.001), shorter postoperative hospital stay (P = 0.026), and postoperative complications (P = 0.035). There was no statistically significant difference between the two groups in terms of pathological type, TNM staging, and number of lymph node dissection.
Conclusion: Three-dimensional reconstruction and localization of pulmonary nodules enables safe and effective individualized thoracoscopic anatomical lung segment resection with a low complication rate, which has good clinical application value.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224268 | PMC |
http://dx.doi.org/10.1186/s12957-023-03035-4 | DOI Listing |
Rev Sci Instrum
January 2025
Optics Research Group, Imaging Physics Department, Delft University of Technology, Van der Waalsweg 8, 2628 CH Delft, The Netherlands.
We demonstrate a broadband implementation of coherent Fourier scatterometry (CFS) using a supercontinuum source. Spectral information can be resolved by splitting the incident field into two pulses with a variable delay and interfering them at the detector after interaction with the sample, bearing similarities with Fourier-transform spectroscopy. By varying the time delay between the pulses, a collection of diffraction patterns is captured in the Fourier plane, thereby obtaining an interferogram for every camera pixel.
View Article and Find Full Text PDFJ Cosmet Dermatol
January 2025
Department of Dermatology, University of Athens School of Medicine, Andreas Sygros Hospital, Athens, Greece.
Objective: NCTF135HA, a versatile polyrevitalizing solution, is a potent agent for enhancing skin quality, radiance, moisture, vitality, and diminishing fine wrinkles caused by aging factors. Data demonstrate a divergence in its application from skin quality enhancement to treatment of vitiligo lesions. To know more precisely about the protocol of use among providers, alone or in combination with other procedures, we performed an international survey.
View Article and Find Full Text PDFFront Vet Sci
January 2025
Department of Clinical Sciences, North Carolina State University College of Veterinary Medicine, Raleigh, NC, United States.
There are a variety of surgical conditions impacting the canine vagina and vestibule that require access through a caudal approach. A standard vertical episiotomy involves making an incision beginning ventral to the anus and extending ventrally through the dorsal commissure of the vulva and into the lumen of the vestibule and distal vagina. The objective of this study was to determine if complex vaginal procedures could be performed via a transverse perineal approach, thus eliminating the need to incise and reconstruct the vulva as performed in a standard episiotomy, and to evaluate the feasibility of vaginal resection with vulvar-sparing vestibular urethrostomy using this transverse approach.
View Article and Find Full Text PDFFront Bioeng Biotechnol
January 2025
Department of Orthopaedics, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical Universit, Guangzhou, China.
Objective: The aim of this study is to assess the kinematic changes in the knee joint during walking in patients with isolated PCL-deficiency (PCLD) to determine the presence of walking-related joint instability (mechanical instability-abnormal displacement form structural damage). Additionally, the study seeks to provide biomechanical insights into the observed differences between subjective and objective assessments.
Methods: 35 healthy volunteers and 27 patients with isolated PCLD (both involved and uninvolved sides) were included in the study.
J Med Imaging (Bellingham)
January 2025
Lund University, Department of Translational Medicine, Medical Radiation Physics, Malmö, Sweden.
Purpose: We aim to investigate the characteristics and evaluate the performance of synthetic mammograms (SMs) based on wide-angle digital breast tomosynthesis (DBT) compared with digital mammography (DM).
Approach: Fifty cases with both synthetic and digital mammograms were selected from the Malmö Breast Tomosynthesis Screening Trial. They were categorized into five groups consisting of normal cases and recalled cases with false-positive and true-positive findings from DM and DBT only.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!