Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Lumbar spinal canal stenosis (LSS) with diffuse idiopathic skeletal hyperostosis (DISH) can require revision surgery because of the intervertebral instability after decompression. However, there is a lack of mechanical analyses for decompression procedures for LSS with DISH.
Methods: This study used a validated, three-dimensional finite element model of an L1-L5 lumbar spine, L1-L4 DISH, pelvis, and femurs to compare the biomechanical parameters (range of motion [ROM], intervertebral disc, hip joint, and instrumentation stresses) with an L5-sacrum (L5-S) and L4-S posterior lumbar interbody fusion (PLIF). A pure moment with a compressive follower load was applied to these models.
Results: ROM of L5-S and L4-S PLIF models decreased by more than 50% at L4-L5, respectively, and decreased by more than 15% at L1-S compared with the DISH model in all motions. The L4-L5 nucleus stress of the L5-S PLIF increased by more than 14% compared with the DISH model. In all motions, the hip stress of DISH, L5-S, and L4-S PLIF had very small differences. The sacroiliac joint stress of L5-S and L4-S PLIF models decreased by more than 15% compared with the DISH model. The stress values of the screws and rods in the L4-S PLIF model was higher than in the L5-S PLIF model.
Conclusions: The concentration of stress because of DISH may influence adjacent segment disease on the nonunited segment of PLIF. A shorter-level lumbar interbody fixation is recommended to preserve ROM; however, it should be used with caution because it could provoke adjacent segment disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2023.05.063 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!