This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the entire range of measured MFI-UF. However, the linearity was not reproducible, and different batches of dextran prepared under the same conditions produced very variable results. For polystyrene solutions, the MFI-UF linearity was verified at the higher range of MFI-UF (>10,000 s/L), while the MFI-UF at the lower range (<5000 s/L) appeared to be underestimated. Secondly, MFI-UF linearity was investigated using natural (surface) water under a wide range of testing conditions (at 20-200 L/m·h using 5-100 kDa membranes). Strong MFI-UF linearity was obtained over the entire range of measured MFI-UF (up to 70,000 s/L). Thus, the MFI-UF method was validated to measure different levels of particulate fouling in RO. However, future research focusing on MFI-UF calibration is still required through the selection, preparation, and testing of heterogeneous mixtures of standard particles.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222867PMC
http://dx.doi.org/10.3390/membranes13050535DOI Listing

Publication Analysis

Top Keywords

mfi-uf linearity
20
mfi-uf
10
mfi-uf method
8
particulate fouling
8
linearity
5
calibrating validating
4
validating mfi-uf
4
method measure
4
measure particulate
4
fouling reverse
4

Similar Publications

Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis.

Membranes (Basel)

May 2023

IHE-Delft Institute for Water Education, Water Supply, Sanitation and Environmental Engineering Department, Westvest 7, 2611 AX Delft, The Netherlands.

This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity.

View Article and Find Full Text PDF

This paper investigated the effect of coagulation on fouling potential and removal of algal organic matter (AOM) in seawater ultrafiltration (UF) systems. AOM harvested from a strain of bloom forming marine diatom, Chaetoceros affinis, was coagulated with ferric chloride under different coagulation modes and conditions. The effect of coagulation on fouling potential was determined with the Modified Fouling Index-Ultrafiltration (MFI-UF).

View Article and Find Full Text PDF

We report on an experimental study of UF membrane fouling by colloidal particles. Deposition colloidal particles during membrane filtration causes a decline in permeate flux. Membrane flux is monitored on a laboratory scale, crossflow employing UF membranes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?