Fiducial markers are utilized for image guided radiotherapy (IGRT) alignment during the delivery of liver stereotactic body radiosurgery (SBRT). There are limited data demonstrating the impact of matching fiducials on the accuracy of liver SBRT. This study quantifies the benefit of fiducial-based alignment and improvements in inter-observer reliability. Nineteen patients with 24 liver lesions were treated with SBRT. Target localization was performed using fiducial markers on cone-beam computed tomography (CBCT). Each CBCT procedure was retrospectively realigned to match both the liver edge and fiducial markers. The shifts were recorded by seven independent observers. Inter-observer variability was analyzed by calculating the mean error and uncertainty for the set-up. The mean absolute Cartesian error observed from fiducial and liver edge-based alignment was 1.5 mm and 5.3 mm, respectively. The mean uncertainty from fiducial and liver edge-based alignment was 1.8 mm and 4.5 mm, respectively. An error of 5 mm or greater was observed 50% of the time when aligning to the liver surface versus 5% of the time when aligning to fiducial markers. Aligning to the liver edge significantly increased the error, resulting in increased shifts when compared to alignment to fiducials. Tumors of 3 cm or farther from the liver dome had higher mean errors when aligned without fiducials (4.8 cm vs. 4.4 cm, = 0.003). Our data support the use of fiducial markers for safer and more accurate liver SBRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10216965PMC
http://dx.doi.org/10.3390/curroncol30050382DOI Listing

Publication Analysis

Top Keywords

fiducial markers
24
liver
11
fiducial
8
delivery liver
8
liver stereotactic
8
stereotactic body
8
liver sbrt
8
liver edge
8
fiducial liver
8
liver edge-based
8

Similar Publications

Traditional marker-based photogrammetry systems often require the attachment and removal of a sticker for each measured point, involving labor-intensive manual steps. This paper presents an innovative approach that utilizes raised, cross-shaped markers, referred to as 'molded markers', directly embedded into composite pieces. In this study, these markers, commonly employed in other industrial processes, serve as fiducial markers for accurate photogrammetry.

View Article and Find Full Text PDF

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Background And Purpose: The aim was to estimate the cost of the external beam radiotherapy (EBRT) in public health care centers in Catalonia (Spain), according to the ESTRO-HERO costing model for 2018.

Materials And Methods: Personnel, equipment, and activity data from 2018 from the 11 RT centers were used, incorporating European mean values adapted to the Catalan context. Secondly, EBRT costs were estimated, incorporating 2023 fractionation technique and scheme usage percentages.

View Article and Find Full Text PDF

Advancements in cryo-EM have stimulated a revolution in structural biology. Yet, for membrane proteins near the cryo-EM size threshold of approximately 40 kDa, including transporters and G-protein coupled receptors, the absence of distinguishable structural features makes image alignment and structure determination a significant challenge. Furthermore, resolving more than one protein conformation within a sample, a major advantage of cryo-EM, represents an even greater degree of difficulty.

View Article and Find Full Text PDF

Verification imaging in prostate MR-only radiotherapy: Are fiducial markers necessary?

Radiography (Lond)

December 2024

Newcastle Upon Tyne Hospitals NHS Foundation Trust, Northern Centre for Cancer Care, Newcastle Upon Tyne, United Kingdom; Newcastle University, Translational and Clinical Research Institute, Newcastle Upon Tyne, United Kingdom.

Purpose/objective: MR-only radiotherapy planning exploits the benefits of MRI soft-tissue delineation, whilst negating the registration inaccuracies caused by MRI CT fusion. Fiducial markers have conventionally been used in prostate radiotherapy to reduce on-treatment image matching variability. However, this is an invasive procedure for the patient, and presents technical difficulties in an MR-only pathway as fiducial markers are difficult to visualise on MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!