Background: Anteroposterior (AP) and lateral fluoroscopies are often used to evaluate the intraoperative location and angulation of the trajectory in percutaneous endoscopic transforaminal lumbar discectomy (PETLD). Although the location of the trajectory shown in fluoroscopy is absolutely accurate, the angulation is not always reliable. This study aimed to evaluate the accuracy of the angle shown in the AP and lateral fluoroscopic views.

Methods: A technical study was performed to assess the angulation errors of PETLD trajectories shown in AP and lateral fluoroscopic views. After reconstructing a lumbar CT image, a virtual trajectory was placed into the intervertebral foramen with gradient-changing coronal angulations of the cephalad angle plane (CACAP). For each angulation, virtual AP and lateral fluoroscopies were taken, and the cephalad angles (CA) of the trajectory shown in the AP and lateral fluoroscopic views, which indicated the coronal CA and the sagittal CA, respectively, were measured. The angular relationships among the real CA, CACAP, coronal CA, and sagittal CA were further demonstrated with formulae.

Results: In PETLD, the coronal CA is approximately equal to the real CA, with a small angle difference and percentage error, whereas the sagittal CA shows a rather large angle difference and percentage error.

Conclusion: The AP view is more reliable than the lateral view in determining the CA of the PETLD trajectory.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210393PMC
http://dx.doi.org/10.1186/s12891-023-06564-xDOI Listing

Publication Analysis

Top Keywords

lateral fluoroscopic
16
fluoroscopic views
12
anteroposterior lateral
8
percutaneous endoscopic
8
endoscopic transforaminal
8
transforaminal lumbar
8
lumbar discectomy
8
lateral fluoroscopies
8
coronal sagittal
8
angle difference
8

Similar Publications

Purpose: Previous studies reported that anterior knee pain (AKP) occurs with an incidence of 32% after opening-wedge high tibial osteotomy (OWHTO). However, the biomechanical effects of this procedure on patellofemoral joints (PFJs) remain unclear. We aimed to quantify the changes in the kinematics and cartilage conditions of the PFJ during stair climbing before and after OWHTO.

View Article and Find Full Text PDF

Background: Advancements in cardiac catheterization have improved survival for pediatric congenital heart disease patients, but the associated ionizing radiation risks necessitate ethical consideration.

Methods: This study presents an empirical model, developed from 3131 unique pediatric procedures, to establish alert levels based on a patient's lateral thickness of the thorax for various procedural categories during diagnostic or interventional cardiac catheterization. The model uses linear regression of logarithmic reference air kinetic energy released per unit mass (KERMA) and air KERMA area product, also referred to as dose area product, to set alert levels at the top 95% and 99% of patient data.

View Article and Find Full Text PDF

Background: Femoroacetabular impingement (FAI) is a well-recognized cause of hip pain in adults. The hip-spine relationship between the femur, pelvis, and lumbosacral spine has garnered recent attention in hip arthroplasty. However, the hip-spine relationship has not been well described in patients with FAI.

View Article and Find Full Text PDF

: Spinal flexibility radiographs are important in adolescent idiopathic scoliosis (AIS) for clinical decision-making. In this study, we introduce a new method, the 'quantitatively controlled standing fulcrum side-bending' test (CSFS test). This is a feasibility study; we aimed to quantify the applied force and track the temporospatial changes in the spine specifically by measuring the continuous change in the Cobb angle (in degrees) during lateral bending.

View Article and Find Full Text PDF

Objective: There are many advantages to stabilize the posterior pelvic ring injuries with a transiliac-transsacral (TITS) screw percutaneously. To identify the correct entry point and insert a guidewire accurately for a TITS screw, we propose a method of specifying the optimal entry point, and introduce a technique of enabling freehand placement of a guidewire with fluoroscopic guidance.

Methods: In this retrospective study, 116 patients who underwent pelvic CT scans and pelvic lateral radiographs at our institution from January 2020 to April 2022 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!