Some considerations on the use of space sound absorbers with next-generation materials reflecting COVID situations in Japan: additional sound absorption for post-pandemic challenges in indoor acoustic environments.

UCL Open Environ

Environmental Acoustic Laboratory, Department of Architecture, Graduate School of Engineering, Kobe University, Rokko, Nada, Kobe 657-8501, Japan.

Published: November 2020

In this study, we first point out the possible acoustic problems associated with the post-pandemic operation of built environments. In particular, we focus on the problem of acoustic deficiency due to the lack of absorption. This deficiency, which is likely to be encountered in most enclosed spaces in a range of establishments, is due to the reduced number of audience members or users of the space as a result of social distancing. As one of the promising solutions to this problem, we introduce a sound absorption technique using three-dimensional (3D) space sound absorbers developed through our recent research projects. Significantly, the type of sound absorber proposed herein is made of materials that are especially suited to hygiene considerations. The materials are microperforated panels (MPPs) and permeable membranes (PMs), both of which are easily washable and sanitised. Furthermore, we point out that 3D-MPP or PM space absorbers possess the additional value of aesthetic designability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10208322PMC
http://dx.doi.org/10.14324/111.444/ucloe.000012DOI Listing

Publication Analysis

Top Keywords

space sound
8
sound absorbers
8
sound absorption
8
sound
5
considerations space
4
absorbers next-generation
4
next-generation materials
4
materials reflecting
4
reflecting covid
4
covid situations
4

Similar Publications

Data on full stationary wave-field measurement of a suspended steel plate punctually loaded.

Data Brief

February 2025

Institut Camille Jordan, UMR-CNRS 5208, École Centrale de Lyon, 36 Avenue Guy de Collongue, 69134, Écully, France.

The dataset presented contains the experimental structural response, in the frequency domain, of a suspended steel plate to a point force excitation. The plate is excited by a mechanical point force generated by a Brüel & kJær shaker with a white noise signal input from 3.125 Hz to 2000 Hz.

View Article and Find Full Text PDF

Novel therapeutic delivery systems and delivery methods to the inner ear are necessary to treat hearing loss and inner ear disorders. However, numerous barriers exist to therapeutic delivery into the bone-encased and immune-privileged environment of the inner ear and cochlea, which makes treating inner ear disorders challenging. Nanoparticles (NPs) are a type of therapeutic delivery system that can be engineered for multiple purposes, and posterior semicircular canal (PSCC) infusion is a method to directly deposit them into the cochlea.

View Article and Find Full Text PDF

Ever since de Saussure [Course in General Lingustics (Columbia University Press, 1916)], theorists of language have assumed that the relation between form and meaning of words is arbitrary. However, recently, a body of empirical research has established that language is embodied and contains iconicity. Sound symbolism, an intrinsic link language users perceive between word sound and properties of referents, is a representative example of iconicity in language and has offered profound insights into theories of language pertaining to language processing, language acquisition, and evolution.

View Article and Find Full Text PDF

Th e Laplace transform formulation proposed by Di and Gilbert [J. Acoust. Soc.

View Article and Find Full Text PDF

Fast response solid electrolyte oxygen sensors with porous thin film electrodes.

Rev Sci Instrum

January 2025

High Enthalpy Flow Diagnostics Group (HEFDiG), Institute of Space Systems, University of Stuttgart, Pfaffenwaldring 29, 70569 Stuttgart, Germany.

A novel solid electrolyte sensor with considerably improved response times is presented. The new so-called eFIPEX [etched flux (Φ) probe experiment] is based on the FIPEX [flux (Φ) probe experiment] sensor applied for the measurement of molecular and atomic oxygen concentrations. A main application is the measurement of atmospheric atomic oxygen aboard sounding rockets up to altitudes of 250 km.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!