Purpose: Biallelic variants in POC1B are rare causes of autosomal recessive cone dystrophy associated with generalized cone system dysfunction. In this report, we describe the clinical characteristics of a Japanese male patient with POC1B-associated retinopathy with relatively preserved cone system function.
Methods: We performed whole-exome sequencing (WES) to identify the disease-causing variants and a comprehensive ophthalmic examination, including full-field and multifocal electroretinography (ffERG and mfERG).
Results: Our WES analysis identified novel compound heterozygous POC1B variants (p.Arg106Gln and p.Arg452Ter) in the patient. His unaffected mother carried the p.Arg452Ter variant heterozygously. The patient experienced decreased visual acuity in his 50s. At the age of 63, his corrected visual acuity was 20/22 in the right and 20/20 in the left eye. Fundus and fundus autofluorescence images for each eye showed no remarkable finding, except for a subtle hyperautofluorescent spot in the fovea of the left eye. Cross-sectional optical coherence tomography demonstrated blurred but a relatively preserved ellipsoid zone. The ffERG showed that amplitudes of rod and standard-flash responses were within the reference range, whereas the cone and light-adapted 30-Hz flicker amplitudes were close to, or slightly below, the reference range. The mfERG revealed substantially reduced responses with relative preservation of central function.
Conclusions: We reported the case of an older patient with POC1B-associated retinopathy, demonstrating late-onset visual decrease, good visual acuity, and relatively preserved cone system function. The disease condition was much milder than previously reported in patients with POC1B-associated retinopathy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10633-023-09936-9 | DOI Listing |
Am J Health Syst Pharm
January 2025
University of North Carolina at Chapel Hill Eshelman School of Pharmacy, Chapel Hill, NC, and University of North Carolina Medical Center, Chapel Hill, NC, USA.
Disclaimer: In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, 82 Gumi-ro 173 beon-gil, Bundang-gu, Bundang‑gu, 13620, Seongnam, Republic of Korea.
Background: This study aims to evaluate the clinical outcome of biofluorescent imaging system (BIS) guided MRONJ surgery through analyzing 3D volumetric changes in CBCT data of bone structure.
Methods: BIS-guided surgery for MRONJ surgery was performed by grinding red-fluorescent area from remained residual bone detected by Qray-pen. CBCT data was collected preoperatively, postoperatively, and at last follow-up more than 3 months of each patient.
Clin Oral Investig
January 2025
Department of Endodontics, Texas A&M College of Dentistry, Dallas, Texas, USA.
Objectives: The objective of this study is to evaluate the incidence and volume of contrast medium extrusion when activated with a laser and to compare these outcomes with those of other irrigation techniques.
Materials And Methods: Sixteen cadaver mandibles containing 116 single-rooted teeth were prepared using conventional rotary instrumentation. The teeth were randomly assigned to four irrigation groups: side-vented needle, sonic irrigation, laser activation at the orifice, and laser activation at the middle third of the canal.
Sci Rep
January 2025
Department of Oral and Maxillofacial Surgery, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Freiburg, Germany.
This experimental phantom study investigates current standard of care protocols in cone beam computed tomography (CBCT), energy-integrating-detector (EID) CT, and photon-counting-detector (PCD) CT regarding their potential in delineation of dental root canals. Artificial accessory canals (diameters: 1000, 600, 400, 300 and 200 μm) were drilled into three bovine teeth mounted on a bovine rib as a jaw substitute. The phantom was scanned in two dental CBCTs, two EID-CTs and a PCD-CT using standard clinical protocols.
View Article and Find Full Text PDFZ Med Phys
January 2025
Department of Radiation Oncology, University of Minnesota, Minneapolis, MN, USA.
The purpose of this work was to evaluate the imaging dose for the Accuray Radixact ClearRT system. Low-contrast resolution and CT number consistency was evaluated as well. CTDI measurements were compared to vendor supplied values, and similar measurements were done on a Varian TrueBeam kV cone-beam CT (CBCT) and a Philips Big Bore CT scanner.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!