A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

PEDOT coated microneedles towards electrochemically assisted skin sampling. | LitMetric

Skin sampling is a diagnostic procedure based on the analysis of extracted skin tissues and/or the observation of biomarkers in bodily fluids. Sampling using microneedles (MNs) that minimize invasiveness is gaining attention over conventional biopsy/blood lancet. In this study, new MNs for electrochemically assisted skin sampling are reported, specifically tailored for combined skin tissue biopsy and interstitial fluid (ISF) extraction. To overcome risks associated with using metal MNs, a highly electroactive, mechanically flexible, and biocompatible organic conducting polymer (CP) coated onto plastic is chosen as an alternative. Two different variants of doped poly(3,4-ethylenedioxythiophene) are coated on polymethyl methacrylate and used in combination as a MN pair with subsequent testing a variety of electrochemical techniques to (i) give real-time information of the MN penetration depth into the skin, and (ii) yield new information on various salts present in the ISF. The MN skin sampler shows the ability to extract ions from the hydrated excised skin as a step towards ISF extraction. The presence of ions was analyzed using X-ray photoelectron spectroscopy. This added chemical information in conjunction with the existing biomarker analysis increases opportunity for disease/condition detection. For example, in the case of psoriasis, information about salt in the skin is invaluable in combination with pathogenic gene expression for diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3tb00485fDOI Listing

Publication Analysis

Top Keywords

skin sampling
12
skin
9
electrochemically assisted
8
assisted skin
8
isf extraction
8
pedot coated
4
coated microneedles
4
microneedles electrochemically
4
sampling
4
sampling skin
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!