A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of the chemiluminescence immunoassay and immunofluorescence test in detecting anti-dsDNA antibodies and assessing the activity of systemic lupus erythematosus. | LitMetric

Objectives: This study aimed to compare the YHLO chemiluminescence immunoassay (CLIA) with the immunofluorescence test (CLIFT) to detect anti-dsDNA antibodies and its correlation with disease activity in systemic lupus erythematosus (SLE).

Method: In total, 208 patients diagnosed with SLE, 110 other autoimmune patients, 70 infectious disorders patients, and 105 healthy people were enrolled in this study. Serum samples were tested using CLIA in a YHLO chemiluminescence system and CLIFT.

Results: The overall agreement between YHLO CLIA and CLIFT was 76.9% (160/208), with a moderate correlation (kappa = 0.530, < 0.001). The sensitivity of YHLO CLIA and CLIFT were 58.2% and 55.3%, respectively. The specificity of YHLO CLIA and CLIFT were 95.1% and 99.3%, respectively. The sensitivity of YHLO CLIA was increased to 66.8% with a specificity of 93.6% when the cut-off value was set at 24 IU/mL. Spearman's correlation coefficient between the quantitative results of YHLO CLIA and the titers of CLIFT was 0.59 ( < .01). A significant correlation was found between the anti-dsDNA results detected by YHLO CLIA and the SLE Disease Activity Index 2000 (SLEDAI-2K). Spearman's correlation coefficient between YHLO CLIA and SLEDAI-2K (r = 0.66, < .01) was higher than that of CLIFT (r = 0.60, < .01).

Conclusions: Good correlation and agreement were found between YHLO CLIA and CLIFT. In addition, there was a significant correlation between YHLO CLIA and the SLE Disease Activity Index, which was superior to that of CLIFT. The YHLO chemiluminescence system is recommended for the assessment of disease activity.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09612033231179888DOI Listing

Publication Analysis

Top Keywords

yhlo clia
36
disease activity
16
clia clift
16
yhlo
12
yhlo chemiluminescence
12
clia
11
chemiluminescence immunoassay
8
immunofluorescence test
8
anti-dsdna antibodies
8
activity systemic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!