A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Updates on bioprosthetic valve fracture. | LitMetric

Updates on bioprosthetic valve fracture.

Expert Rev Cardiovasc Ther

Department of Cardiology, Saint. Luke's Mid America Heart Institute and University of Missouri, Kansas City, MO, USA.

Published: June 2023

Introduction: Valve-in-valve (VIV) transcatheter valve replacement has emerged as a feasible and potentially safer treatment option for failed bioprosthetic surgical valves (BSVs). However, the VIV procedure carries an inherent risk of prosthesis-patient mismatch (PPM). Bioprosthetic valve fracture (BVF) and bioprosthetic valve remodeling (BVR) by either fracturing or stretching the surgical valve ring allows for a more optimal expansion of the transcatheter heart valve (THV) and beneficial effects on post-implant valve hemodynamics and perhaps long-term valve durability.

Areas Covered: This is an expanded overview of BVF and BVR to facilitate VIV transcatheter aortic valve replacement (TAVR), with detailed discussion on lessons learned from bench testing studies and translation to procedural technique and clinical experience incorporating up-to-date evidence and experience with BVF in non-aortic positions.

Expert Opinion: BVF and BVR improve valve hemodynamics following VIV-TAVR, with timing of BVF being an important determinant of procedure safety and efficacy; however, longer-term data are needed to determine long-term clinical outcomes including mortality, valve hemodynamics, and valve reintervention. In addition, further research will be needed to understand the safety and efficacy of these procedures in any new generation BSV or THV and to better define the role of these techniques in the pulmonic, mitral, and tricuspid positions.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14779072.2023.2217356DOI Listing

Publication Analysis

Top Keywords

valve
12
bioprosthetic valve
12
valve hemodynamics
12
valve fracture
8
viv transcatheter
8
valve replacement
8
bvf bvr
8
safety efficacy
8
bvf
5
updates bioprosthetic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!