Air trapping is a common finding radiologists encounter on CT imaging of the thorax. This term is used when there are geographic areas of differing attenuation within the lung parenchyma. Most commonly, this is the result of abnormal retention of air due to complete or partial airway obstruction from small airway pathologies. Perfusional differences due to underlying vascular diseases could also result in these appearances, and hence, inspiratory and full expiratory phase CT studies are required to accurately diagnose air trapping. It is important to note that this can occasionally be present in healthy patients. Multiple diseases are associated with air trapping. Determining the aetiology relies on accurate patient history and concomitant findings on CT. There is currently no consensus on accurate assessment of the severity of air trapping. The ratio of mean lung density between expiration and inspiration on CT and the change in lung volume have demonstrated a positive correlation with the presence of small airway disease. Treatment and resultant patient outcome depend on the underlying aetiology, and hence, radiologists need to be familiar with the common causes of air trapping. This paper outlines the most common disease processes leading to air trapping, including Constrictive bronchiolitis, Hypersensitivity pneumonitis, DIPNECH, and Post-infectious (Swyer-James/Macleod). Various diseases result in the air trapping pattern seen on the expiratory phase CT scan of the thorax. Combining patient history with other concomitant imaging findings is essential for accurate diagnosis and to further guide management.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1754-9485.13540DOI Listing

Publication Analysis

Top Keywords

air trapping
32
small airway
16
air
9
airway diseases
8
diseases result
8
expiratory phase
8
patient history
8
history concomitant
8
trapping
7
airway
5

Similar Publications

Carbon dioxide (CO) accumulation and emission are well-known features of deep lakes, making them a significant unavoidable carbon source to the atmosphere. In the case of meromictic lakes, degassing devices are installed to controllably release through a pipe the CO trapped in the bottom waters. Otherwise, the gas is emitted diffusely at the air-water surface or accidentally through a limnic eruption when the saturation limit is reached.

View Article and Find Full Text PDF

Background: Clinical severity and progression of lung disease in cystic fibrosis (CF) are significantly influenced by the degree of lung inflammation. Non-invasive quantitative diagnostic tools are desirable to differentiate structural and inflammatory lung changes in order to help prevent chronic airway disease. This might also be helpful for the evaluation of longitudinal effects of novel therapeutics.

View Article and Find Full Text PDF

Harnessing deep learning to detect bronchiolitis obliterans syndrome from chest CT.

Commun Med (Lond)

January 2025

Division of Pulmonary Medicine, Department of Medicine, Lausanne University Hospital (CHUV), University of Lausanne (UNIL), Lausanne, Switzerland.

Background: Bronchiolitis Obliterans Syndrome (BOS), a fibrotic airway disease that may develop after lung transplantation, conventionally relies on pulmonary function tests (PFTs) for diagnosis due to limitations of CT imaging. Deep neural networks (DNNs) have not previously been used for BOS detection. This study aims to train a DNN to detect BOS in CT scans using an approach tailored for low-data scenarios.

View Article and Find Full Text PDF

Comparison of Methods of Eliciting Vital Capacity: Forced Versus Slow Vital Capacity.

J Voice

January 2025

Department of Statistics, Purdue University, Mathematical Sciences Building, 150 N. University Street, Room 231, West Lafayette, IN 47907.

Background: Methods to elicit the vital capacity (VC) include forced vital capacity (FVC) and slow vital capacity (SVC). Because the FVC maneuver can be affected by air trapping or inefficiencies in lung emptying vs. the SVC, the SVC-FVC difference may be substantial and diagnostically meaningful in elderly individuals and patients with respiratory obstruction.

View Article and Find Full Text PDF

Stable Air Plastron Prolongs Biofluid Repellency of Submerged Superhydrophobic Surfaces.

Langmuir

January 2025

School of Chemical Engineering, Department of Chemistry and Materials Science, Aalto University, Tietotie 3 Espoo 02150, Finland.

Superhydrophobic surfaces find applications in numerous biomedical scenarios, requiring the repellence of biofluids and biomolecules. Plastron, the trapped air between a superhydrophobic surface and a wetting liquid, plays a pivotal role in biofluid repellency. A key challenge, however, is the often short-lived plastron stability in biofluids and the lack of knowledge surrounding it.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!