Temporally consistent sequence-to-sequence translation of cataract surgeries.

Int J Comput Assist Radiol Surg

Computer Science, Technical University Darmstadt, Fraunhoferstraße 5, 64283, Darmstadt, Hessen, Germany.

Published: July 2023

Purpose: Image-to-image translation methods can address the lack of diversity in publicly available cataract surgery data. However, applying image-to-image translation to videos-which are frequently used in medical downstream applications-induces artifacts. Additional spatio-temporal constraints are needed to produce realistic translations and improve the temporal consistency of translated image sequences.

Methods: We introduce a motion-translation module that translates optical flows between domains to impose such constraints. We combine it with a shared latent space translation model to improve image quality. Evaluations are conducted regarding translated sequences' image quality and temporal consistency, where we propose novel quantitative metrics for the latter. Finally, the downstream task of surgical phase classification is evaluated when retraining it with additional synthetic translated data.

Results: Our proposed method produces more consistent translations than state-of-the-art baselines. Moreover, it stays competitive in terms of the per-image translation quality. We further show the benefit of consistently translated cataract surgery sequences for improving the downstream task of surgical phase prediction.

Conclusion: The proposed module increases the temporal consistency of translated sequences. Furthermore, imposed temporal constraints increase the usability of translated data in downstream tasks. This allows overcoming some of the hurdles of surgical data acquisition and annotation and enables improving models' performance by translating between existing datasets of sequential frames.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10329626PMC
http://dx.doi.org/10.1007/s11548-023-02925-yDOI Listing

Publication Analysis

Top Keywords

temporal consistency
12
image-to-image translation
8
cataract surgery
8
consistency translated
8
image quality
8
downstream task
8
task surgical
8
surgical phase
8
translated
6
translation
5

Similar Publications

Zero echo time (zero-TE) pulse sequences provide a quiet and artifact-free alternative to conventional functional magnetic resonance imaging (fMRI) pulse sequences. The fast readouts (<1 ms) utilized in zero-TE fMRI produce an image contrast with negligible contributions from blood oxygenation level-dependent (BOLD) mechanisms, yet the zero-TE contrast is highly sensitive to brain function. However, the precise relationship between the zero-TE contrast and neuronal activity has not been determined.

View Article and Find Full Text PDF

The corpus callosum, a major white matter region central to cognitive function, is vulnerable to aging. Using zeitgeber time (ZT) aligned with environmental light/dark cycles, we investigated temporal gene expression patterns in the corpus callosum of young (5-month-old) and aged (24-month-old) mice using RNA-seq. Comparative analysis revealed more differentially expressed genes across ZT pairs in young mice than aged mice.

View Article and Find Full Text PDF

Evaluation of the Nijmegen Cochlear Implant Questionnaire in Danish.

Int Arch Otorhinolaryngol

January 2025

Research Unit for ORL - Head and Neck Surgery and Audiology, Odense University Hospital, Odense, Denmark.

 The Nijmegen cochlear implant questionnaire (NCIQ) is a quantifiable self-assessment health-related quality of life (HRQoL) tool used internationally to determine quality of life (QoL) in cochlear implant (CI) users and to evaluate the implant's subjective benefits.  This study aimed to validate the Danish version of the questionnaire (DA-NCIQ) with a test-retest including 60 participants (30 CI users and 30 CI candidates).  The intraclass correlation coefficients (ICC) were calculated to evaluate the temporal stability of the participants' answers and the internal consistency of the questionnaire domains was determined using the Cronbach alpha in order to compare these results with the NCIQ's other language versions.

View Article and Find Full Text PDF

MRI delta radiomics during chemoradiotherapy for prognostication in locally advanced cervical cancer.

BMC Cancer

January 2025

Mohn Medical Imaging and Visualization Centre (MMIV), Department of Radiology, Haukeland University Hospital, Jonas Lies vei 65, Bergen, 5021, Norway.

Background: Effective diagnostic tools for prompt identification of high-risk locally advanced cervical cancer (LACC) patients are needed to facilitate early, individualized treatment. The aim of this work was to assess temporal changes in tumor radiomics (delta radiomics) from T2-weighted imaging (T2WI) during concurrent chemoradiotherapy (CCRT) in LACC patients, and their association with progression-free survival (PFS). Furthermore, to develop, validate, and compare delta- and pretreatment radiomic signatures for prognostic modeling.

View Article and Find Full Text PDF

We are not only passively immersed in a sensorial world, but we are active agents that directly produce stimulations. Understanding what is unique about sensory consequences can give valuable insight into the action-perception-cycle. Sensory attenuation is the phenomenon that self-produced stimulations are perceived as less intense compared to externally-generated ones.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?