Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: We developed model eyes using six polymer materials to determine which materials were most appropriate in simulating real human sclera and extraocular muscle (EOM).
Methods: Five three-dimensional (3-D) printed polymers (FlexFill, PolyFlex, PCTPE, Soft PLA, and NinjaFlex) and one silicone material were systematically tested by board-certified ophthalmologists and senior ophthalmology residents. Material testing included scleral passes with 6-0 Vicryl sutures through each eye model. Participants completed a survey designed to collect demographic data, subjective assessment of each material's accuracy in simulating real human sclera and EOM, and a ranking for each polymer material to identify which would be most suitable for an ophthalmic surgery training tool. The Wilcoxon signed-rank test was conducted to determine if there was a statistically significant difference in the distribution of ranks between the polymer materials.
Results: The distribution of ranks for silicone material's "sclera" and "EOM" components were statistically significantly higher than that of all other polymer materials (all p < 0.05). Silicone material received the highest rank for both "sclera" and "EOM" components. Survey results indicated that the silicone material effectively simulated real human tissue.
Conclusion: Silicone model eyes performed better than 3-D printed polymers as an educational tool for incorporation into a microsurgical training curriculum. Silicone models provide a low-cost teaching tool that allows for independent practice of microsurgical techniques without requiring a wet-laboratory facility.